Key result
Risk-stratification using a novel algorithm identified high-risk NSVT patients, with tachyarrhythmic events occurring in 28.1% of the ICD group vs 0.8% of the observation group.
Why the study?
Does a novel risk-stratification algorithm appropriately identify high-risk patients for prophylactic ICD implantation among those with non-sustained ventricular tachycardia?
Cohort (n=222)
Does a novel risk-stratification algorithm appropriately identify high-risk patients for prophylactic ICD implantation among those with non-sustained ventricular tachycardia?
A novel risk-stratification algorithm for patients with non-sustained ventricular tachycardia successfully identified high-risk individuals who subsequently experienced significantly more tachyarrhythmic events, supporting its utility for selecting candidates for prophylactic ICD implantation.
Answers are grounded in this paper and cite their sources.
May support novel NSVT risk stratification for ICD selection; leaves open randomized confirmation before practice change.
BACKGROUND: The therapeutic strategy for non-sustained ventricular tachycardia (NSVT), considered as a risk-stratifier for sudden cardiac death (SCD), still remains undetermined. METHODS AND RESULTS: In the present study 222 of 4,079 patients (5.4%) hospitalized with NSVT during 2002 to 2004 were prospectively evaluated using an algorithm for risk-stratification according to each type of structural heart disease. The algorithm comprises the left ventricular ejection fraction, signal-averaged electrocardiography, programmed ventricular stimulation and the family history of SCD. Of the 222 patients, 151 (68.0%) were successfully risk-stratified and 32 patients consequently received an implantable cardioverter defibrillator (ICD) (21.2%; algorithm-ICD group). The remaining 119 patients without an ICD (algorithm-observation group) were observed. During 27.7+/-11.4 months of follow-up, the patients in the algorithm-ICD group had a significantly higher prevalence of tachyarrhythmic events than did those in the algorithm-observation group (9/32 vs 1/119; p<0.05). In the algorithm-ICD group, 2, 1 and 6 patients experienced an SCD, aborted SCD and appropriate ICD intervention, respectively, while there was only 1 SCD in the algorithm-observation group. CONCLUSIONS: The proposed algorithm for risk-stratification of patients with NSVT may be feasible for appropriate selection of high-risk patients and candidates for prophylactic ICD implantation.
No takes yet. Share an insight, caveat, or question.
Ueno et al. (2007) conducted a cohort in Non-sustained ventricular tachycardia (NSVT) (n=222). Risk-stratification algorithm guiding ICD implantation vs. Algorithm-observation group (no ICD) was evaluated on Tachyarrhythmic events (p=<0.05). Risk-stratification using a novel algorithm identified high-risk NSVT patients, with tachyarrhythmic events occurring in 28.1% of the ICD group vs 0.8% of the observation group.
Synapse has enriched 10 related papers. Consider them for comparative context: