Key result
SENSE acceleration enables single breath-hold LV T1 mapping but overestimates global values by ~25 ms.
Why the study?
Current practice to obtain LV native and post-contrast T1 and T2 requires single-slice readouts with multiple breath-holds.
Does a multi-slice parallel-imaging approach with a 72-channel receive-array coil reduce breath-holds while maintaining accurate T1 and T2 mapping compared to standard single-slice readouts?
Cross-Sectional (n=21)
Yes
Does a multi-slice parallel-imaging approach with a 72-channel receive-array coil reduce breath-holds while maintaining accurate T1 and T2 mapping compared to standard single-slice readouts?
Answers are grounded in this paper and cite their sources.
A novel 72-channel receive-array coil with SENSE acceleration enables multi-slice cardiac T1 and T2 mapping in significantly fewer breath-holds, though with slight overestimations in relaxation times.
Introduction: Current practice to obtain left ventricular (LV) native and post-contrast T1 and T2 comprises single-slice readouts with multiple breath-holds (BHs). We propose a multi-slice parallel-imaging approach with a 72-channel receive-array to reduce BHs and demonstrate this in healthy subjects and hypertrophic cardiomyopathy (HCM) patients. Methods: A T1/T2 phantom was scanned at 3 T using a 16-channel and a novel 72-channel coil to assess the impact of different coils and acceleration factors on relaxation times. 16-18 healthy participants (8 female, age 28.4 ± 5.1 years) and 3 HCM patients (3 male, age 55.3 ± 4.2 years) underwent cardiac-MRI with the 72-channel coil, using a Modified Look-Locker scan with a shared inversion pulse across 3 slices and a Gradient-Spin-Echo scan. Acceleration was done by sensitivity encoding (SENSE) with accelerations 2, 4, and 6. LV T1 and T2 values were analyzed globally, per slice, and in 16 segments, with SENSE = 2 as the reference. SENSE = 4 and 6 enabled T1 mapping of three slices in a single BH, and T2 mapping of three slices within two BHs. In healthy subjects, T1 and T2 values varied. We found an average overestimation of T1 in 3 slices of 25 ± 87 ms for SENSE = 4 and 30 ± 103 ms using SENSE = 6, as compared to SENSE = 2. Acceleration resulted in decreased signal-to-noise; however, visually insignificant and without increased incidence of SENSE-artifacts. T2 was overestimated by 2.1 ± 5.0 ms for SENSE = 4 and 6.4 ± 9.7 ms using SENSE = 6, as compared to SENSE = 2. Native and post-contrast T1 measurements with SENSE = 4 and ECV quantification in HCM patients was successful. Conclusion: The 72-channel receiver-array coil with SENSE = 4 and 6, enabled LV-tissue characterization in three slices. Pre- and post-contrast T1 maps were obtained in a single BH, while T2 required two BHs.
No takes yet. Share an insight, caveat, or question.
Klarenberg et al. (2023) conducted a cross-sectional in Healthy volunteers and Hypertrophic Cardiomyopathy (HCM) (n=21). 72-channel receive array coil with SENSE=4 and 6 acceleration vs. Standard SENSE=2 acceleration was evaluated on Global mean native T1 values (ms) (Mean bias 25 ms, p=<0.001). A 72-channel receiver-array coil with SENSE acceleration factors of 4 and 6 enabled left ventricular T1 mapping in three slices within a single breath-hold, with a mean global T1 overestimation of 25 ms for SENSE=4 compared to SENSE=2.
Synapse has enriched 10 related papers. Consider them for comparative context: