Key result
Evolut PRO and Sapien 3 Ultra show similar clinical outcomes across sexes, despite varying device success.
Why the study?
Evidence regarding sex-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking.
Does sex modify the treatment effect of self-expanding versus balloon-expandable valves on 30-day and 1-year clinical outcomes in patients undergoing transfemoral TAVI?
Observational (n=1,897)
Yes
Does sex modify the treatment effect of self-expanding versus balloon-expandable valves on 30-day and 1-year clinical outcomes in patients undergoing transfemoral TAVI?
Absolute Event Rate: 10.2% vs 9.8%
Sex does not significantly modify the 1-year clinical outcomes of self-expanding versus balloon-expandable TAVI devices, though balloon-expandable valves may have lower 30-day device success in males compared to self-expanding valves.
Sex does not modify 1-year TAVI outcomes by valve type; leaves open sex-specific selection for device success.
Background Evidence regarding sex-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study sought to evaluate the impact of sex on the treatment effect of Evolut-PRO/PRO+ (PRO) or Sapien 3 Ultra (ULTRA) devices on clinical outcomes. Methods Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter multinational registry including patients undergoing latest-iteration PRO or ULTRA implantation. Overall, 1174 out of 1897 patients were matched based on valve type and compared according to sex, while 470 males and 630 females were matched and compared according to valve type. Thirty-day and 1-year outcomes were evaluated. Results In both PRO and ULTRA group, males had a higher comorbidity burden, while females had smaller aortic root. Both 30-day (device success [DS], early safety outcome, permanent pacemaker implantation [PPI], patient-prosthesis mismatch [PPM], paravalvular regurgitation [PVR], bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke and heart failure hospitalization) did not differ according to sex in both valve groups. However, male sex decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction 0.047). A higher risk of 30-day PPI and 1-year stroke, and a lower risk of PPM was observed in PRO versus ULTRA, regardless of sex. No other differences were noted. Conclusions Sex did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, with the exception of 30-day DS that was decreased in males (versus females) receiving ULTRA (versus PRO).
No takes yet. Share an insight, caveat, or question.
Adamo et al. (2023) conducted an observational in Aortic stenosis (n=1,897). Evolut PRO/PRO+ (Self-Expanding Valve) vs. Sapien 3 Ultra (Balloon-Expandable Valve) was evaluated on 1-year composite of all-cause death, disabling stroke, and heart failure hospitalization (in males). Sex did not modify the treatment effect of Evolut PRO versus Sapien 3 Ultra on clinical outcomes, except for 30-day device success which was decreased in males receiving Sapien 3 Ultra.