Key result
Rapid pacing-induced abrupt loss of constant fusion in the surface ECG was observed in 64.1% of patients and was invariably associated with interruption of ventricular tachycardia.
Why the study?
Does rapid pacing at a critical cycle length cause abrupt loss of constant fusion and orthodromic block in patients with sustained monomorphic VT?
Observational (n=45)
Does rapid pacing at a critical cycle length cause abrupt loss of constant fusion and orthodromic block in patients with sustained monomorphic VT?
The abrupt loss of constant fusion during transient entrainment of VT is a reliable electrocardiographic hallmark of orthodromic block as the mechanism of pacing-induced interruption.
May mark orthodromic block during VT entrainment; supports consensus yet leaves open prospective validation.
Sustained monomorphic ventricular tachycardia (VT) can be frequently entrained and interrupted with rapid pacing and the mechanism of the pacing-induced interruption is considered to be due to orthodromic block. This study focused on the incidence of VT which was interrupted at a critical cycle length and was characterized by an abrupt loss of constant fusion in the surface electrocardiogram (ECG), and the role of orthodromic block as the cause of such characteristic change and interruption of VT was analyzed. Among 45 consecutive patients with symptomatic VT, rapid pacing was performed in 43 VTs of 39 patients. The exit was mapped as the earliest site of the activation during VT and an electrode catheter was located at the site. Rapid pacing was performed at progressively shorter cycle lengths in steps of 10 msec until VT was interrupted and the timing of the orthodromic and direct capture was compared at the exit. Abrupt loss of constant fusion was observed in 25 of 39 patients (64.1%): and the loss was invariably associated with interruption of VT. When the timings of the activation of the exit were compared, which were measured from the preceding (n-1) stimulus as the time reference, the direct capture was relatively delayed compared to that of the orthodromic capture. This finding suggests that orthodromic block is the cause of the direct capture as well as the pacing-induced interruption of VT. In the remaining 13 patients (35.9%), the surface ECG showed a gradual transition into the fully paced QRS morphology. The direct capture was confirmed in the non-fused beats, but it was not necessarily associated with interruption of VT. The interval from the stimulus to the entrained electrogram at the exit showed a gradual prolongation until the exit was finally captured directly from the pacing site. The confirmation of constant fusion followed by abrupt loss in ECG can be a reliable hallmark of orthodromic block as the cause of the interruption of VT during transient entrainment at a critical paced cycle length.
No takes yet. Share an insight, caveat, or question.
Yamaura et al. (2001) conducted an observational in Symptomatic ventricular tachycardia (n=45). Rapid pacing was evaluated on Abrupt loss of constant fusion in the surface ECG during rapid pacing. Rapid pacing-induced abrupt loss of constant fusion in the surface ECG was observed in 64.1% of patients and was invariably associated with interruption of ventricular tachycardia.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: