PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 1, 1994Circulation63 citationsOpen Access

Abnormalities of cardiac sympathetic function in pacing-induced heart failure as assessed by 123Imetaiodobenzylguanidine scintigraphy.

View Full Paper
WSWilliam W. SimmonsMFMichael R. FreemanEGEtienne A. Grima

Key Result

In a canine model, pacing-induced heart failure was associated with reduced cardiac MIBG activity (0.17 vs 0.29 counts/MBq/pixel at baseline; P=0.0001) and increased distribution heterogeneity.

Structured PICO

P
Population
23 dogs: 8 normal dogs (group 1) and 15 dogs with heart failure induced by right ventricular pacing at 250 beats per minute either continuously for 3 weeks (group 2) or intermittently for 7 weeks (group 3)
I
Intervention
[123I]metaiodobenzylguanidine (MIBG) and 201Tl planar and tomographic cardiac imaging
C
Comparator
Normal dogs (group 1) and baseline measurements
O
Outcome
Cardiac MIBG activity and left ventricular tissue norepinephrine concentrationsurrogate

In a canine model of pacing-induced heart failure, MIBG scintigraphy demonstrated severe cardiac adrenergic dysfunction and correlated with LV tissue norepinephrine levels, suggesting its utility as a noninvasive method for assessing cardiac sympathetic innervation.

Main Result

Absolute Event Rate: 0.17% vs 0.29%

p-value: p=.0001

Abstract

BACKGROUND: Increased activity of the sympathetic nervous system contributes significantly to the pathophysiology of heart failure. However, cardiac efferent sympathetic function has not been well characterized in this disorder. In this study, we evaluated cardiac sympathetic innervation using 123Imetaiodobenzylguanidine (MIBG) and compared this with left ventricular (LV) tissue norepinephrine concentration and myocardial perfusion, assessed by 201Tl, in a canine model of heart failure. METHODS AND RESULTS: Planar and tomographic cardiac imaging was performed for MIBG and 201Tl in 23 dogs: 8 normal dogs (group 1) and 15 dogs with heart failure induced by right ventricular pacing at 250 beats per minute either continuously for 3 weeks (group 2) or intermittently for 7 weeks (group 3). Plasma and LV tissue norepinephrine concentrations were also measured. Scintigraphic studies in group 2 demonstrated reduced cardiac MIBG activity at heart failure (0.17 +/- 0.04 versus 0.29 +/- 0.05 counts per megabecquerel per pixel at baseline, mean +/- SD; P = .0001), whereas thallium activity was unchanged from baseline. This reduction in cardiac MIBG activity with heart failure was associated with increased intraimage variability in the distribution of MIBG activity (21 +/- 8% versus 13 +/- 7% at baseline, mean +/- SD; P = .0001). The MIBG heart-to-lung ratio was calculated for all groups to control for the inhibitory effect that plasma norepinephrine has on the neuronal uptake of MIBG. There was a positive correlation between LV tissue norepinephrine and the MIBG heart-to-lung ratio (r = .67; P < .001; n = 22), for which the group 2 heart failure animals had the lowest values. No relation existed between plasma norepinephrine concentration and the MIBG heart-to-lung ratio. In addition, regional LV tissue norepinephrine concentration and MIBG activity were both lowest at the apex in normal (group 1) and heart failure (group 2) dogs. The MIBG heart-to-lung ratio also correlated inversely with cardiac filling pressure (r = -.59; P < .05) and heart rate (r = -.65; P < .01) and positively with cardiac output (r = .53; P < .05). CONCLUSIONS: Heart failure is associated with severe cardiac adrenergic dysfunction manifested by reduced MIBG activity and increased heterogeneity in the LV distribution of MIBG. Furthermore, MIBG scintigraphy is a simple noninvasive method for assessing global and regional LV tissue norepinephrine levels.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Simmons et al. (1994) studied Pacing-induced heart failure (n=23). [123I]metaiodobenzylguanidine (MIBG) scintigraphy vs. Baseline / Normal dogs was evaluated on Cardiac MIBG activity (counts per megabecquerel per pixel) (p=.0001). In a canine model, pacing-induced heart failure was associated with reduced cardiac MIBG activity (0.17 vs 0.29 counts/MBq/pixel at baseline; P=0.0001) and increased distribution heterogeneity.

synapsesocial.com/papers/6a15bfb6a2f71238514eb142https://doi.org/10.1161/01.cir.89.6.2843
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Regional Distribution of Catecholamines in the Dog Heart1965 · 83 citations
  2. 2Carotid sinus baroreceptor sensitivity in experimental heart failure.1990 · 167 citations
  3. 3Abnormalities in systemic norepinephrine kinetics in human congestive heart failure1988 · 83 citations
  4. 4Regional Uptake of [3H]Norepinephrine by the Canine Left Ventricle1982 · 13 citations
  5. 5Baroreceptor function in congestive heart failure: effect on neurohumoral activation and regional vascular resistance.1987 · 153 citations