Key result
CMR-3D imaging improved the delineation of conducting channels prior to VT ablation compared to CMR-2D, identifying a mean of 2.06 vs 1.06 channels, which more closely matched electroanatomic mapping.
Why the study?
Does CMR-3D improve the delineation of conducting channels compared to CMR-2D in patients with structural heart disease referred for VT ablation?
Observational (n=30)
Does CMR-3D improve the delineation of conducting channels compared to CMR-2D in patients with structural heart disease referred for VT ablation?
CMR-3D imaging provides higher spatial resolution and improves the delineation of conducting channels prior to VT ablation compared to standard CMR-2D, despite having lower signal-to-noise and contrast-to-noise ratios.
Answers are grounded in this paper and cite their sources.
CMR-3D may aid pre-ablation planning in structural heart disease; hypothesis-generating and requires prospective validation before practice change.
Introduction: Delayed enhanced cardiac magnetic resonance using 2D sequences (CMR-2D) represents the standard for clinical characterization of myocardium. However, 2D images suffer from insufficient spatial resolution in the Z-axis and missregistration that preclude appropriate visualization of conducting channels (CC), which are critical for ventricular tachycardia (VT) ablation. We studied whether characterization using a free breathing 3D delayed enhanced navigator gated sequence (CMR-3D) proved to be superior than CMR-2D sequences. Methods: We included 30 consecutive patients with structural heart disease referred for VT ablation. Myocardial characterization was conducted prior to the ablation procedure in a 3T-scanner using CMR-2D and CMR-3D sequences, yielding a spatial resolution of 1.4 x 1.4 x 5 mm and 1.4 x 1.4 x 1.4 mm respectively. The scar components, core and border zone (BZ), were quantified in both datasets using the 60% and 40% threshold of maximum pixel intensity, respectively. The signal to noise ratio (SNR) and contrast to noise ratio (CNR) was analyzed in a representative slice in both sequences. For both set of images a 3D reconstruction of the scar was obtained and an electrophysiologyst identified potential CC and compared them to those depicted in the electroanatomic map (EAM). Results: We found no significant differences between the mass of the scar core in the 2D and 3D sequence (mean 7.33±6.56 vs 6.74±5.22 grams respectivelly, p=0.612). However, the BZ mass was smaller in the 2D than in the 3D sequence (9.38±7.72 vs 12.10±7.81 grams; p=0.019). The SNR was higher in the 2D dataset as compared to the 3D (42.93±27.34 vs 28.09±12.85; p=0.005) as well as the CNR (37.01±26.20 vs 20.15±11.41; p=0.001). The mean number of CC identified in the 3D dataset was higher than in the 2D, and closer to those depicted in the EAM (1.06±0.75 for CMR-2D vs 2.63±1.41 for EAM, p=0.005; and 2.06±1.25 for CMR-3D vs 2.63±1.41 for EAM p=0.088). Conclusion: Despite the higher SNR and CNR of standard CMR-2D images, the higher spatial resolution provided by CMR-3D images improved the overall delineation of CC prior to VT ablation.
No takes yet. Share an insight, caveat, or question.
Andreu et al. (2013) conducted an observational in Structural heart disease referred for VT ablation (n=30). CMR-3D (free breathing 3D delayed enhanced navigator gated sequence) vs. CMR-2D (delayed enhanced cardiac magnetic resonance using 2D sequences) was evaluated on Mean number of conducting channels (CC) identified. CMR-3D imaging improved the delineation of conducting channels prior to VT ablation compared to CMR-2D, identifying a mean of 2.06 vs 1.06 channels, which more closely matched electroanatomic mapping.