Key result
Doppler echocardiography showed that left ventricular filling patterns in infants with ventricular septal defect differed significantly from normal controls, indicating altered compliance.
Why the study?
Do left ventricular diastolic filling patterns differ in infants with ventricular septal defect compared to normal infants?
Observational (n=29)
Do left ventricular diastolic filling patterns differ in infants with ventricular septal defect compared to normal infants?
Infants with ventricular septal defect exhibit abnormal left ventricular diastolic filling patterns on Doppler echocardiography, suggesting insufficient adaptation of left ventricular compliance to volume overload.
May prompt diastolic monitoring in VSD infants; leaves open prognostic impact and need for prospective studies.
To evaluate left ventricular diastolic filling in infants with ventricular septal defect, which has yet to be documented, we measured various Doppler echocardiographic indexes from transmitral flow in the following groups: 10 infants with ventricular septal defect without pulmonary hypertension; 10 infants with ventricular septal defect with pulmonary hypertension; and 9 normal infants to serve as controls. The peak A, total velocity time integral, E area, and A area in patients without pulmonary hypertension were all significantly larger than those in controls. The peak ratio E/A, and 1/3 filling fraction, in patients without pulmonary hypertension were significantly lower than in controls. The peak A, A area, and deceleration time in patients with pulmonary hypertension were significantly larger than in patients without pulmonary hypertension and controls. The peak E/A, area E/A, and 1/3 filling fraction in patients with pulmonary hypertension were significantly lower than in those without pulmonary hypertension and controls. The index of left ventricular mass, as well as the index of end-diastolic left ventricular wall thickness, correlated strongly with peak A, A area, and deceleration time. The ratio between the systolic pulmonary and systemic pressures correlated strongly with peak A, A area, peak E/A, area E/A, and 1/3 filling fraction. These results demonstrated that the patterns of left ventricular filling in infants with ventricular septal defect were different from those in normal infants, and suggested that the abnormal patterns may indicate the insufficiency of adaptation of left ventricle (increase of left ventricular compliance) for volume overload in the presence of a ventricular septal defect.
No takes yet. Share an insight, caveat, or question.
Ito et al. (1998) conducted an observational in Ventricular septal defect (n=29). Doppler echocardiography vs. Normal infants was evaluated on Doppler echocardiographic indexes of left ventricular diastolic filling. Doppler echocardiography showed that left ventricular filling patterns in infants with ventricular septal defect differed significantly from normal controls, indicating altered compliance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: