Key result
An electronic order set for administering prothrombin complex concentrate for vitamin K antagonist-associated intracerebral hemorrhage significantly reduced the median time to administration from 83 to 45 minutes.
Why the study?
Does an electronic order set reduce time to administration of PCC in adults with VKA-associated ICH?
Observational (n=31)
No
Does an electronic order set reduce time to administration of PCC in adults with VKA-associated ICH?
Absolute Event Rate: 45% vs 83%
p-value: p=0.02
Implementation of an electronic order set for PCC administration in VKA-associated ICH significantly reduced time to treatment and improved dosing accuracy.
Supports order sets for faster PCC in VKA-ICH; leaves open outcome benefits in this observational cohort.
Background: Vitamin K antagonist (VKA)–associated intracerebral hemorrhages (ICHs) are more likely to expand and are associated with higher mortality than primary ICH. Prompt reversal of anticoagulant effect with prothrombin complex concentrate (PCC) may promote hemostasis and decrease hematoma expansion. The aim of this study was to evaluate the impact of an electronic order set designed to standardize and facilitate more timely reversal of coagulopathy in VKA-associated ICH. Methods: We identified all adults who received PCC for VKA-associated ICH from June 2012 to June 2015 at University of California San Francisco Medical Center, which included a period before and after an electronic order set became available in 2014. We abstracted baseline demographics and clinical data from electronic health records. The primary outcome was time from radiographic identification of ICH to administration of PCC. Results: Thirty-one patients received PCC for VKA-associated ICH, including 17 patients before and 14 patients after the order set became available. Baseline demographics and clinical features were similar. Order set use was associated with a significant decrease in the time from identification of ICH on imaging to the administration of PCC (median 83 vs 45 minutes; P = .02), more accurate dosing (29.4% vs 92.9%; P < .01), and a shorter time from the PCC order to follow-up international normalized ratio (INR) testing (median 164 vs 85 minutes, P = .001). Conclusion: An electronic order set for administering PCC for VKA-associated ICH was associated with significantly faster time to PCC administration and increased dosing accuracy.
No takes yet. Share an insight, caveat, or question.
Vitt et al. (2017) conducted an observational in Vitamin K antagonist-associated intracerebral hemorrhage (n=31). Mandatory electronic order set for prothrombin complex concentrate (PCC) vs. Stand-alone manual medication order (pre-intervention) was evaluated on Time from radiographic identification of ICH to administration of PCC (minutes) (p=0.02). An electronic order set for administering prothrombin complex concentrate for vitamin K antagonist-associated intracerebral hemorrhage significantly reduced the median time to administration from 83 to 45 minutes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: