Key result
Point-of-care INR monitoring in OAC-ICH showed close agreement with central laboratories and reduced median time for complete reversal from 120 to 28 minutes.
Why the study?
Does point-of-care INR monitoring improve the speed and efficiency of PCC dose-titration for OAC reversal in patients with OAC-ICH compared to central laboratory measurements?
Observational (n=191)
Does point-of-care INR monitoring improve the speed and efficiency of PCC dose-titration for OAC reversal in patients with OAC-ICH compared to central laboratory measurements?
Absolute Event Rate: 28% vs 120%
Point-of-care INR monitoring provides a faster and more efficient method for titrating prothrombin complex concentrate to reverse vitamin K antagonists in patients with intracerebral hemorrhage.
POC INR may accelerate OAC reversal in ICH; leaves open outcome benefits pending prospective trials.
OBJECTIVE: Rapid reversal of the anticoagulatory effect of vitamin K antagonists represents the primary emergency treatment for oral anticoagulant-related intracerebral hemorrhage (OAC-ICH). Predicting the amount of prothrombin complex concentrate (PCC) needed to reverse OAC in individual patients is difficult, and repeated international normalized ratio (INR) measurements in central laboratories (CLs) are time-consuming. Accuracy and effectiveness of point-of-care INR coagulometers (POCs) for INR reversal in OAC-ICH have not been evaluated. METHODS: In phase 1, the agreement of emergency POC and CL INR measurements was determined. In phase 2, stepwise OAC reversal was performed with PCC using a predetermined dosing schedule. Concordance of POC and CL INR measurements during reversal and time gain due to POC were determined. RESULTS: In phase 1 (n = 165), Bland-Altman analysis showed close agreement between POCs and CLs (mean INR deviation 0.04). In phase 2 (n = 26), POCs caused a median initial net time gain of 24 minutes for the start of treatment with PCC. Median time for POC-documented complete OAC reversal was 28 minutes, compared with 120 minutes for CLs. Bland-Altman analysis between POCs and CLs revealed a mean INR deviation of 0.13 during stepwise PCC administration. POCs tended to slightly overestimate the INR, especially at higher INR levels. Remarkably, POC-guided reversal led to a median reduction of 30.5% of PCC dose compared with the a priori dose calculation. Hematomas enlarged in 20% of patients. INTERPRETATION: POC INR monitoring is a fast, effective, and economic means of PCC dose-titration in OAC-ICH. Larger studies examining the clinical efficacy of this procedure are warranted.
No takes yet. Share an insight, caveat, or question.
Rizos et al. (2010) conducted an observational in Oral anticoagulant-related intracerebral hemorrhage (OAC-ICH) (n=191). Point-of-care INR coagulometers (POCs) vs. Central laboratories (CLs) was evaluated on Time for documented complete OAC reversal (minutes). Point-of-care INR monitoring in OAC-ICH showed close agreement with central laboratories and reduced median time for complete reversal from 120 to 28 minutes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: