Key result
Rapid atrial pacing significantly increased If current densities in canine pulmonary vein sleeve cardiac myocytes compared to controls (-2.66 vs -0.91 pA/pF, P<0.01), contributing to ectopic activity.
Answers are grounded in this paper and cite their sources.
Rapid atrial pacing increases I(f) current and spontaneous action potentials in pulmonary vein cardiac myocytes, which may contribute to triggering and maintaining atrial fibrillation.
OBJECTIVE: To investigate the characteristics of ectopic automaticity and cation current (I(f)) of cardiac myocytes from pulmonary vein sleeves (PVs) in canines with atrial fibrillation. METHODS: The canines (8-10 years old) were subjected to long-term, rapid atrial pacing (RAP) for 10 weeks, which induced the atrial fibrillation model. Disassociation of PVs of canines yielded single cardiac myocytes from a Landengorff column. Action potential, I(f) and hyperpolarisation activated cyclic nucleotide-gated (HCN) currents were measured with the patch-clamp technique. RESULTS: Compared with the control group, cardiac myocytes from the RAP canine PVs had spontaneous diastolic depolarization, shorter action potential duration, and larger I(f) densities. In the group of RAP cells, the half maximal activation potential (V(1/2)) was found to be less negative (-105.5 ± 5.2 mV) compared to control cells (-87.3 ± 4.9 mV). Current densities of I(f) were increased significantly by β-adrenergic receptor stimulation with isoproterenol and caused an acceleration of current activation. In contrast, I(f) currents in the RAP were reduced by carvedilol, a selective beta-adrenergic receptor. Another important finding is that HCN4-based channels may make a significant contribution to I(f) in PVs cells, but not HCN2. Meanwhile, HCN4 current significantly increases in canine PVs cardiac myocytes with RAP. CONCLUSIONS: The spontaneous action potential and larger I(f) current were observed in the PVs cardiac myocytes using RAP, which may contribute to more ectopic activity events to trigger and maintain atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Li et al. (2013) studied Atrial fibrillation (n=12). Rapid atrial pacing (RAP) vs. Non-pacing control was evaluated on If current densities at -120 mV (p=<0.01). Rapid atrial pacing significantly increased If current densities in canine pulmonary vein sleeve cardiac myocytes compared to controls (-2.66 vs -0.91 pA/pF, P<0.01), contributing to ectopic activity.
Synapse has enriched 10 related papers. Consider them for comparative context: