Why the study?
Does instructing observers to measure a non-hemispherical 'urchinoid' distance rather than a hemispherical radius improve the accuracy of PISA measurements in mitral regurgitation?
Systematic Review (n=11)
Does instructing observers to measure a non-hemispherical 'urchinoid' distance rather than a hemispherical radius improve the accuracy of PISA measurements in mitral regurgitation?
Absolute Event Rate: -28% vs 7%
p-value: p=<0.0005
Current guideline instructions to measure a hemispherical PISA radius lead to significant underestimation of mitral regurgitation severity, which can be improved by using non-hemispherical measurement instructions and multi-frame averaging.
Hemispherical PISA radius instructions underestimate MR severity; challenges guidelines and supports non-hemispherical measurement in practice and trials.
BACKGROUND: Guidelines for quantifying mitral regurgitation (MR) using "proximal isovelocity surface area" (PISA) instruct operators to measure the PISA radius from valve orifice to Doppler flow convergence "hemisphere". Using clinical data and a physically-constructed MR model we (A) analyse the actually-observed colour Doppler PISA shape and (B) test whether instructions to measure a "hemisphere" are helpful. METHODS AND RESULTS: In part A, the true shape of PISA shells was investigated using three separate approaches. First, a systematic review of published examples consistently showed non-hemispherical, "urchinoid" shapes. Second, our clinical data confirmed that the Doppler-visualized surface is non-hemispherical. Third, in-vitro experiments showed that round orifices never produce a colour Doppler hemisphere. In part B, six observers were instructed to measure hemisphere radius rh and (on a second viewing) urchinoid distance (du) in 11 clinical PISA datasets; 6 established experts also measured PISA distance as the gold standard. rh measurements, generated using the hemisphere instruction significantly underestimated expert values (-28%, p<0.0005), meaning r(h)(2) was underestimated by approximately 2-fold. du measurements, generated using the non-hemisphere instruction were less biased (+7%, p=0.03). Finally, frame-to-frame variability in PISA distance was found to have a coefficient of variation (CV) of 25% in patients and 9% in in-vitro data. Beat-to-beat variability had a CV of 15% in patients. CONCLUSIONS: Doppler-visualized PISA shells are not hemispherical: we should avoid advising observers to measure a hemispherical radius because it encourages underestimation of orifice area by approximately two-fold. If precision is needed (e.g. to detect changes reliably) multi-frame averaging is essential.
No takes yet. Share an insight, caveat, or question.
Moraldo et al. (2012) conducted a systematic review in Mitral regurgitation (n=11). Hemisphere instruction for PISA measurement vs. Non-hemisphere (urchinoid) instruction was evaluated on Bias in PISA distance measurement compared to expert values (p=<0.0005).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: