Key result
Post-LVAD aortic incompetence is linked to ~20% higher aortic valve leaflet shear stress.
Why the study?
Progressive aortic valve disease remains a concern in LVAD patients, and aortic incompetence predicts mortality and readmissions but remains a challenging clinical problem.
Do localized flow patterns (wall shear stress and oscillatory shear index) differ between LVAD patients who develop de novo aortic incompetence and those who do not?
Case-Control (n=29)
No
Do localized flow patterns (wall shear stress and oscillatory shear index) differ between LVAD patients who develop de novo aortic incompetence and those who do not?
Patient-specific computational fluid dynamics reveal that localized wall shear stress on aortic leaflet tips is significantly higher in LVAD patients who develop aortic incompetence, challenging previous notions of highly disturbed flow in the aortic root.
Answers are grounded in this paper and cite their sources.
Localized leaflet wall shear stress elevation may predict aortic incompetence risk in LVAD patients; challenges root flow disturbance assumptions and requires prospective validation.
Background: Progressive aortic valve disease has remained a persistent cause of concern in patients with left ventricular assist devices. Aortic incompetence (AI) is a known predictor of both mortality and readmissions in this patient population and remains a challenging clinical problem. Methods: Ten left ventricular assist device patients with de novo aortic regurgitation and 19 control left ventricular assist device patients were identified. Three-dimensional models of patients’ aortas were created from their computed tomography scans, following which large-scale patient-specific computational fluid dynamics simulations were performed with physiologically accurate boundary conditions using the SimVascular flow solver. Results: The spatial distributions of time-averaged wall shear stress and oscillatory shear index show no significant differences in the aortic root in patients with and without AI (mean difference, 0.67 dyne/cm 2 [95% CI, −0.51 to 1.85]; P =0.23). Oscillatory shear index was also not significantly different between both groups of patients (mean difference, 0.03 [95% CI, −0.07 to 0.019]; P =0.22). The localized wall shear stress on the leaflet tips was significantly higher in the AI group than the non-AI group (1.62 versus 1.35 dyne/cm 2 ; mean difference [95% CI, 0.15–0.39]; P <0.001), whereas oscillatory shear index was not significantly different between both groups (95% CI, −0.009 to 0.001; P =0.17). Conclusions: Computational fluid dynamics serves a unique role in studying the hemodynamic features in left ventricular assist device patients where 4-dimensional magnetic resonance imaging remains unfeasible. Contrary to the widely accepted notions of highly disturbed flow, in this study, we demonstrate that the aortic root is a region of relatively stagnant flow. We further identified localized hemodynamic features in the aortic root that challenge our understanding of how AI develops in this patient population.
No takes yet. Share an insight, caveat, or question.
Shad et al. (2021) conducted a case-control in Left ventricular assist device (LVAD) patients (n=29). Aortic incompetence (AI) vs. No aortic incompetence was evaluated on Localized wall shear stress on the leaflet tips (MD 0.27, 95% CI 0.15-0.39, p=<0.001). LVAD patients who developed aortic incompetence had higher localized wall shear stress on the aortic valve leaflet tips compared to those without aortic incompetence.
Synapse has enriched 10 related papers. Consider them for comparative context: