Key result
Enhanced motion tracking reduces PWV estimation errors by ~35% versus traditional methods.
Why the study?
Frame rate limitations in focused ultrasound cause discontinuous pulse wave estimation with traditional motion tracking, reducing the measurement accuracy of transit time-based local PWV in the common carotid artery.
The proposed enhanced motion tracking method significantly improves the accuracy of ultrasonic transit time-based local pulse wave velocity measurements in simulated models.
Answers are grounded in this paper and cite their sources.
Refines ultrasonic PWV estimation in animal models; leaves open translation to clinical cardiovascular assessment.
Pulse wave velocity (PWV) is commonly used to quantify the elasticity of the common carotid artery (CCA), and its accurate measurement is helpful for the early prevention and diagnosis of cardiovascular diseases. Owing to the limitation of the frame rate in the focused ultrasound scanning, the pulse wave (PW) estimated from the ultrasonic radio frequency (RF) signals of the vessel wall is discontinuous with the traditional motion tracking (TMT) method. This factor reduces the measurement accuracy of ultrasonic transit time (TT)-based local PWV. In this study, an enhanced motion tracking (EMT) method for the PW estimation is proposed to improve the local PWV measurement of the CCA. Firstly, the normalized cross-correlation function (NCCF) between the tracking window in the first frame and the comparison windows in the nth frame is calculated using 1-D normalized cross-correlation algorithm, and the spline interpolation is performed on this NCCF to increase its spatial density. Then, the wall displacement of nth frame is estimated by the spatial shift corresponding to the interpolation induced peak location of the interpolated NCCF. Finally, the PW is composed of the wall displacements of all frames within a cardiac cycle. In the experiments, the EMT method is used to estimate the PWs at different beam positions along the CCA by processing the ultrasonic RF signals simulated from the PW propagation ultrasound simulation models of young subjects. And the local PWVs are measured by the ultrasonic TT method. Compared with the TMT-based results, the mean value of normalized root mean square errors between the estimated and theoretical PWVs based on the EMT decrease by 35.14%. In conclusion, the proposed EMT method is helpful to provide more accurate ultrasonic TT-based local PWV measurement.
No takes yet. Share an insight, caveat, or question.
Gu et al. (2021) studied Carotid artery elasticity assessment. Enhanced motion tracking (EMT) method vs. Traditional motion tracking (TMT) method was evaluated on Normalized root mean square errors between estimated and theoretical PWVs (35.14% decrease). An enhanced motion tracking method for pulse wave estimation decreased the mean normalized root mean square errors between estimated and theoretical pulse wave velocities by 35.14% compared to traditional methods.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: