Key result
Atrial defibrillation shocks synchronized to normal QRS complexes avoided VF, whereas shocks during LBBB or RBBB required preceding RR intervals >345 ms at baseline to prevent VF.
Why the study?
Does synchronization of atrial defibrillation shocks to narrow vs wide QRS complexes affect the induction of ventricular fibrillation in a canine model?
Does synchronization of atrial defibrillation shocks to narrow vs wide QRS complexes affect the induction of ventricular fibrillation in a canine model?
Atrial defibrillation shocks synchronized to narrow QRS complexes appear safe, but wide QRS complexes (LBBB/RBBB) require specific timing or longer preceding RR intervals to avoid inducing ventricular fibrillation.
Answers are grounded in this paper and cite their sources.
May support narrow-QRS synchronization to avoid VF in atrial defibrillation; leaves open human translation for wide-complex timing.
BACKGROUND: The potential ventricular proarrhythmic effect of atrial defibrillation shocks (ADS) remains a concern with automatic internal atrial defibrillation. Optimal R-wave synchronization alone may not be sufficient to prevent the induction of ventricular fibrillation (VF). METHODS AND RESULTS: The proarrhythmic effect of ADS synchronized to normally conducted QRS complexes (NQRS) and to supraventricular complexes with left or right bundle-branch block (L/RBBB) was investigated in a canine atrial pacing study. Short-long-short, single premature, and burst pacing protocols from the high right atrium were performed at baseline, during isoproterenol infusion, and after intravenous procainamide. The ADS were delivered between decapolar catheters in the coronary sinus and lateral right atrium. They were initially delivered 20 milliseconds (ms) after the end of the last conducted QRS complex and then scanned decrementally through that complex until VF was induced. For NQRS complexes, VF occurred only when the ADS were delivered at or before the onset of the QRS complex and never during the complex itself. In the presence of LBBB or RBBB, VF was induced by ADS delivered at the onset of or within the first 45 ms of the QRS complex in 16 animals. The longest RR (VV) intervals preceding ADS-induced VF were 345 ms at baseline and 380 ms after procainamide. CONCLUSIONS: In this study, ADS synchronized to NQRS complexes appeared to be safe regardless of the preceding RR interval. In the presence of LBBB or RBBB, RR intervals preceding the ADS of >345 ms at baseline and >380 ms in the presence of procainamide would have been required to avoid VF. Alternatively, ADS delivered 50 ms after the onset of the RV electrogram appeared to be safe in all circumstances regardless of the preceding RR interval.
No takes yet. Share an insight, caveat, or question.
Keelan et al. (1997) studied Simulated Atrial Fibrillation (n=16). Atrial defibrillation shocks (ADS) vs. Normally conducted QRS vs L/RBBB was evaluated on Induction of ventricular fibrillation (VF). Atrial defibrillation shocks synchronized to normal QRS complexes avoided VF, whereas shocks during LBBB or RBBB required preceding RR intervals >345 ms at baseline to prevent VF.