Key result
4D flow CMR accurately quantifies trans-valvular flow in AF without significant stroke volume bias.
Why the study?
The role of 4D flow cardiovascular MRI in assessing trans-valvular flow in patients with AF had not previously been assessed.
Does 4D flow cardiovascular MRI accurately quantify trans-valvular flow in patients with atrial fibrillation compared to healthy controls?
Cross-Sectional (n=18)
No
Does 4D flow cardiovascular MRI accurately quantify trans-valvular flow in patients with atrial fibrillation compared to healthy controls?
4D flow cardiovascular MRI is feasible and provides internally consistent quantification of trans-valvular flow in patients with rate-controlled atrial fibrillation.
Answers are grounded in this paper and cite their sources.
Supports 4D flow CMR feasibility for flow quantification in AF; hypothesis-generating and should not yet change practice.
<ns4:p> <ns4:bold>Background</ns4:bold> : Four-dimensional (4D) flow cardiovascular magnetic resonance imaging (MRI) is an emerging technique used for intra-cardiac blood flow assessment. The role of 4D flow cardiovascular MRI in the assessment of trans-valvular flow in patients with atrial fibrillation (AF) has not previously been assessed. The purpose of this study was to assess the feasibility, image quality, and internal validity of 4D flow cardiovascular MRI in the quantification of trans-valvular flow in patients with AF. </ns4:p> <ns4:p> <ns4:bold>Methods</ns4:bold> : Patients with AF and healthy controls in sinus rhythm underwent cardiovascular MRI, including 4D flow studies. Quality assurance checks were done on the raw data and streamlines. Consistency was investigated by trans-valvular flow assessment between the mitral valve (MV) and the aortic valve (AV). </ns4:p> <ns4:p> <ns4:bold>Results</ns4:bold> : Eight patients with AF (88% male, mean age 62±13 years, mean heart rate (HR) 83±16 beats per minute (bpm)) were included and compared with ten healthy controls (70% male, mean age 41±20 years, mean HR 68.5±9 bpm). All scans were of either good quality with minimal blurring artefacts, or excellent quality with no artefacts. No significant bias was observed between the AV and MV stroke volumes in either healthy controls (–4.8, 95% CI –15.64 to 6.04; P=0.34) or in patients with AF (1.64, 95% CI –4.7 to 7.94; P=0.56). A significant correlation was demonstrated between MV and AV stroke volumes in both healthy controls (r=0.87, 95% CI 0.52 to 0.97; P=0.001) and in AF patients (r=0.82, 95% CI 0.26 to 0.97; P=0.01). </ns4:p> <ns4:p> <ns4:bold>Conclusions</ns4:bold> : In patients with AF, 4D flow cardiovascular MRI is feasible with good image quality, allowing for quantification of trans-valvular flow. </ns4:p>
No takes yet. Share an insight, caveat, or question.
Mills et al. (2021) conducted a cross-sectional in Atrial fibrillation (n=18). 4D flow cardiovascular magnetic resonance imaging vs. Healthy controls in sinus rhythm was evaluated on Bias between aortic valve and mitral valve stroke volumes (95% CI -4.7 to 7.94, p=0.56). Four-dimensional flow cardiovascular MRI is feasible and allows accurate quantification of trans-valvular flow in patients with atrial fibrillation, demonstrating no significant bias between aortic and mitral valve stroke volumes.
Synapse has enriched 10 related papers. Consider them for comparative context: