Key result
Inappropriate implantable cardioverter-defibrillator shocks did not significantly affect the composite of all-cause mortality or cardiac hospitalization (adjusted HR 1.06) compared to no inappropriate shocks.
Why the study?
Does the occurrence of inappropriate ICD shocks increase the composite of all-cause mortality or cardiac hospitalization in patients implanted with an ICD?
Observational (n=148)
No
Does the occurrence of inappropriate ICD shocks increase the composite of all-cause mortality or cardiac hospitalization in patients implanted with an ICD?
Effect estimate: HR 1.06 (95% CI 0.49-2.29)
Absolute Event Rate: 35.3% vs 25.4%
p-value: p=0.877
Inappropriate ICD shocks, while common and primarily driven by atrial fibrillation, did not significantly impact long-term mortality or cardiac hospitalization in this Korean cohort.
Reassures against altering management for inappropriate ICD shocks alone; leaves open causal effects in broader populations.
Limited data are available on inappropriate shocks in Korean patients implanted with an implantable cardioverter-defibrillator (ICD). We investigated the impact of inappropriate shocks on clinical outcomes. This retrospective, single-center study included 148 patients treated between October 1999 and June 2011. The primary outcome was a composite event of all-cause mortality or hospitalization for any cardiac reason. The median follow-up duration was 29 months (interquartile range: 8 to 53). One or more inappropriate shocks occurred in 34 (23.0%) patients. A history of atrial fibrillation was the only independent predictor of inappropriate shock (hazard ratio [HR]: 4.16, 95% confidence interval [CI]: 1.89-9.15, P < 0.001). Atrial fibrillation was the most common cause of inappropriate shock (67.7%), followed by supraventricular tachycardia (23.5%), and abnormal sensing (8.8%). A composite event of all-cause mortality or hospitalizations for any cardiac reason during follow-up was not significantly different between patients with or without inappropriate shock (inappropriate shock vs no inappropriate shock: 35.3% vs 35.4%, adjusted HR: 1.06, 95% CI: 0.49-2.29, P = 0.877). Inappropriate shocks do not affect clinical outcomes in patients implanted with an ICD, although the incidence of inappropriate shocks is high.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2012) conducted an observational in Implantable cardioverter-defibrillator (ICD) recipients (n=148). Inappropriate ICD shock vs. No inappropriate ICD shock was evaluated on Composite of all-cause mortality or hospitalization for any cardiac reason (HR 1.06, 95% CI 0.49-2.29, p=0.877). Inappropriate implantable cardioverter-defibrillator shocks did not significantly affect the composite of all-cause mortality or cardiac hospitalization (adjusted HR 1.06) compared to no inappropriate shocks.