Key result
Low-flow irrigated ablation (2 ml/min) provided favorable lesion characteristics for posterior left atrial ablation compared to high-flow (17 ml/min) without increasing adverse events (p<0.05).
Why the study?
Does low-flow irrigated ablation improve lesion characteristics without increasing adverse events compared to high-flow ablation in thin atrial tissue?
Observational (n=386)
Does low-flow irrigated ablation improve lesion characteristics without increasing adverse events compared to high-flow ablation in thin atrial tissue?
Low-flow irrigated ablation creates favorable transmural lesions in thin atrial tissue without increasing the risk of adverse events compared to high-flow ablation.
May support low-flow irrigation for posterior LA lesions without added risk; hypothesis-generating for clinical outcomes.
OBJECTIVES: The authors sought to investigate the effect of low irrigation flow rate on lesion characteristics and ablation outcomes in a clinicopathological study. BACKGROUND: Irrigated ablation produces deeper lesions compared with nonirrigated ablation, which may not be desirable in the thin-walled posterior left atrium (LA), where collateral esophageal injury is possible. METHODS: Lesions were placed on the smooth posterior right atrium in 20 swine and posterior LA in 60 patients at a maximum power of 20 to 25 W with either: 1) power-controlled ablation at an irrigation flow rate of 17 ml/min (high-flow group 10 swine; n = 40) or 2) temperature-controlled ablation at an irrigation flow rate of 2 ml/min (low-flow group 10 swine; n = 20). Safety and efficacy was also compared in 326 patients undergoing AF ablation using high-flow (n = 160) or low-flow settings (n = 166) for posterior LA ablation. RESULTS: Low-flow, compared with high-flow, lesions in swine had a higher incidence of lesions with: impedance fall ≥10 Ω, loss of pace capture, electrograms characteristic of transmural lesions, and visible lesions on anatomic inspection (p < 0.05 for all). Low-flow lesions had a maximal diameter at the endocardial surface, whereas high-flow lesions had a maximal diameter at the epicardial surface. In humans, impedance, pace capture, and transmurality data also strongly favored low-flow lesions. There was no difference in acute pulmonary vein isolation, complications, or 12-month arrhythmia-free survival between the groups. CONCLUSIONS: Low-flow irrigated ablation provides favorable lesion characteristics for posterior LA ablation without increasing the risk of adverse events.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2017) conducted an observational in Atrial Fibrillation (n=386). Low-flow irrigated ablation vs. High-flow irrigated ablation (17 ml/min) was evaluated on Lesion characteristics (impedance fall ≥10 Ω, loss of pace capture, transmurality) and 12-month arrhythmia-free survival (p=<0.05). Low-flow irrigated ablation (2 ml/min) provided favorable lesion characteristics for posterior left atrial ablation compared to high-flow (17 ml/min) without increasing adverse events (p<0.05).