Key result
Concordant LV lead placement cuts 2-year death or HF hospitalization ~62% in CRT.
Why the study?
Image-guided approaches targeting left ventricular lead placement at the site of latest mechanical activation during cardiac resynchronization therapy have shown inconsistent clinical outcomes.
Does LV lead placement concordant with latest mechanical activation improve clinical and echocardiographic outcomes in patients undergoing CRT?
Meta-Analysis (n=1,355)
Does LV lead placement concordant with latest mechanical activation improve clinical and echocardiographic outcomes in patients undergoing CRT?
Concordant LV lead placement at the site of latest mechanical activation during CRT is associated with significantly reduced death or HF hospitalization and improved echocardiographic parameters compared to discordant placement.
Answers are grounded in this paper and cite their sources.
Supports concordant LV lead placement in CRT to reduce death or HF hospitalization; confirms benefit despite prior inconsistent trials.
BACKGROUND: For cardiac resynchronization therapy (CRT), image-guided approaches targeting left ventricular (LV) lead placement at the site of latest mechanical activation had inconsistent outcomes. We examined evidence for improved CRT outcomes when LV lead placement concordant with latest mechanical activation occurred. METHODS: A review of EMBASE and PubMed was performed for randomized controlled trials or prospective observational studies from October 2008 through October 2020 comparing outcomes with concordant versus discordant LV lead placement. Meta-analyses were performed to assess the association between concordance and death, death or heart failure (HF) hospitalization, ≥ 15% reduction in LV end systolic volume (LVESV), and changes in LVESV or ejection fraction (LVEF). RESULTS: From 5897 citations, nine publications (eight studies) with 1355 patients were selected; 975 with a concordant LV lead and 380 with a discordant lead. Mean age was 66-68 years, 82% were male, and 64% had ischemic cardiomyopathy. Meta-analyses demonstrated a statistically significant reduction in death/HF hospitalization at 2 years (OR 0.38; 95% CI 0.16, 0.92) and LVESV at 6 months (mean difference [MD] -13.4%; 95% CI -6.7%, -20.0%), and an increase in LVEF (MD 4.03; 95% CI 0.77, 7.30) with the concordant LV lead. There were trends toward decreased death at 2 years (OR 0.49; 95% CI 0.19, 1.23) and ≥ 15% reduction in LVESV at 6 months (OR 3.81; 95% CI 0.24, 61.24) with concordant LV lead placement. CONCLUSION: A concordant LV lead was associated with better CRT outcomes. Further study of feasible methods to achieve LV lead concordance is needed.
No takes yet. Share an insight, caveat, or question.
LaPointe et al. (2022) conducted a meta-analysis in Heart failure (n=1,355). Concordant left ventricular lead placement vs. Discordant left ventricular lead placement was evaluated on Death or heart failure hospitalization at 2 years (OR 0.38, 95% CI 0.16-0.92, p=0.022). Concordant left ventricular lead placement during cardiac resynchronization therapy reduced the odds of death or heart failure hospitalization at 2 years compared to discordant placement.
Synapse has enriched 10 related papers. Consider them for comparative context: