Answers are grounded in this paper and cite their sources.
Experimental study investigates crack patterns and strain responses in 3D-printed tunnels under vertical loads, suggesting structural implications.
To investigate the failure characteristics of 3D-printed concrete utility tunnels under loading, a 1:25 scaled model was designed using similarity theory. Vertical loading tests were conducted under soil lateral confinement, and the load–displacement curves, discrete-point strain responses, and crack evolution process were obtained. The test results show that the structure successfully undergoes an elastic stage, a crack development stage, and a plastic failure stage. The incorporated polypropylene fibers exert a bridging effect, enabling the component to retain a certain load-bearing capacity after cracking. Crack distribution was highly heterogeneous: cracks were densest on the top slab, widest on the side walls, and multi-directional on the inner wall. A clear correspondence exists between strain response and crack distribution, with tensile strain zones highly coinciding with crack opening zones. The failure mode generally agrees with the “top slab compression–side wall tensile cracking” characteristic of traditional closed-frame structures. However, the wall thickness deviations induced by the 3D printing process are amplified during internal force redistribution in the statically indeterminate structure, resulting in markedly asymmetric failure of the left and right side walls.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: