Why the study?
Data evaluating the benefit and harm of performing concomitant PCI during TAVI to limit repeated vascular access risk are scarce.
Does concomitant PCI during TAVI result in similar VARC-3 endpoints and long-term mortality compared to a stepwise PCI approach in TAVI patients?
Does concomitant PCI during TAVI result in similar VARC-3 endpoints and long-term mortality compared to a stepwise PCI approach in TAVI patients?
Concomitant PCI during TAVI appears safe and feasible, with similar technical success, device success, and 3-year mortality compared to a stepwise approach.
Similar 3-year mortality across PCI strategies during TAVI; leaves open whether concomitant approach is safe and feasible pending randomized trials.
BACKGROUND: Patients undergoing transcatheter aortic valve implantation (TAVI) frequently have coronary artery disease requiring percutaneous coronary intervention (PCI). Usually, PCI and TAVI are performed in two separate procedures and current studies are investigating potential benefits regarding the order. However, the two interventions may also be performed simultaneously, thereby limiting the risk associated with repeated vascular access. Data evaluating benefit and harm of concomitant procedures are scarce. AIMS: Therefore, this study aimed to evaluate concomitant PCI (coPCI) in TAVI patients regarding Valve Academic Research Consortium 3 (VARC-3) endpoints and long-term mortality. METHODS: A total of 2233 consecutive TAVI patients from the EVERY-VALVE registry were analyzed according to the VARC-3 endpoint definitions. A total of 274 patients had undergone TAVI and concomitant PCI (coPCI group). They were compared to 226 TAVI patients who had received PCI within 60 days before TAVI in a stepwise approach (swPCI group) and to the remaining 1733 TAVI patients who had not undergone PCI recently (noPCI group). RESULTS: Overall median age was 81.4 years, median Society of Thoracic Surgeons score was 4.0%. Patients in the coPCI and in the swPCI group were predominantly male with reduced left-ventricular ejection fraction. Rates of VARC-3 composite endpoints technical success and 30-day device success were comparable between all three groups. Mortality rates at 3 years after TAVI were similar (coPCI, 34.2% vs. swPCI, 31.9% vs. noPCI, 34.0% p = 0.84). CONCLUSIONS: coPCI during TAVI seems comparable in a retrospective analysis. Compared to a stepwise approach, it has similar rates of composite endpoints technical success and device success as well as long-term mortality.
No takes yet. Share an insight, caveat, or question.
Fischer et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: