Why the study?
Does [1-11C]palmitate PET provide equivalent palmitate flux measurements to continuous infusion of [U-13C]palmitate in human volunteers?
Does [1-11C]palmitate PET provide equivalent palmitate flux measurements to continuous infusion of [U-13C]palmitate in human volunteers?
[1-11C]palmitate PET does not provide equivalent palmitate kinetic results compared to the continuous infusion [U-13C]palmitate approach for measuring free fatty acid flux.
Answers are grounded in this paper and cite their sources.
[1-11C]palmitate PET cannot substitute for [U-13C]palmitate infusion to measure FFA flux; leaves open whether refined modeling achieves equivalence.
PET radiopharmaceuticals can noninvasively measure free fatty acid (FFA) tissue uptake. Investigators often use PET scan-derived data to calculate FFA flux. We tested whether the [1- 11 C]palmitate PET measures of palmitate flux provide results equivalent to a continuous infusion of [U- 13 C]palmitate. Nine volunteers participated in study 1 to evaluate whether a rapidly (10–20 s) given bolus of [1- 11 C]palmitate affects calculated flux results. Thirty volunteers participated in study 2, which was identical to study 1 except that the [1- 11 C]palmitate bolus was given over 1 min. Volunteers in both studies also received a continuous intravenous infusion of [U- 13 C]palmitate. Plasma palmitate concentrations and enrichment were measured by liquid chromatography-mass spectrometry. The PET/CT images were analyzed on a workstation running PMOD. Palmitate flux was estimated using PET time-activity curve (TAC) data from regions of interest in the left ventricle (LV) and aorta both with and without hybrid TACs that employed the 11 CO 2 -corrected data for the first 5 min and the 11 CO 2 -corrected blood radioactivity for the remainder of the PET scan. Palmitate flux in study 1 measured with PET [1- 11 C]palmitate and [U- 13 C]palmitate were not correlated, and the PET [1- 11 C]palmitate flux was significantly less than the [U- 13 C]palmitate measured flux. In study 2, the palmitate flux using PET [1- 11 C]palmitate hybrid LV models provided closer mean estimates of [U- 13 C]palmitate measured flux. The best PET calculation approaches predicted 64% of the interindividual variance in [U- 13 C]palmitate measured flux. Palmitate kinetics measured using [1- 11 C]palmitate/PET do not provide the same palmitate kinetic results as the continuous infusion [U- 13 C]palmitate approach.
No takes yet. Share an insight, caveat, or question.
Han et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: