This case demonstrates the rare occurrence of phase-3 and phase-4 retrograde block in a second concealed accessory pathway following an initially successful ablation.
Answers are grounded in this paper and cite their sources.
Alerts to possible multiple concealed pathways with phase-dependent block after initial success; leaves open generalizability beyond this case.
We report a patient with concealed Wolff-Parkinson-White syndrome who, following catheter ablation, demonstrated phase-3 and phase-4 retrograde block in a concealed accessory pathway. After an initial 'apparently successful' ablation, retrograde conduction was through the atrioventricular node during constant ventricular pacing. Ventricular extrastimulus testing was performed at a basic drive cycle length of 600 ms. Unexpectedly, ventricular extrastimuli at coupling intervals of 440-380 ms were conducted retrogradely over an accessory pathway, consistent with a phase-3 and phase-4 retrograde block in the accessory pathway. Residual accessory pathway conduction was eliminated in a single ablation session.
No takes yet. Share an insight, caveat, or question.
Azegami et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: