Key result
Oscillatory pacing in a human ventricular action potential model demonstrated that action potential duration and calcium transient amplitude oscillations behave as two coupled harmonic oscillators.
Why the study?
The bidirectional coupling between APD and CTA makes it difficult to determine which leads EC coupling dynamics under variable pacing, and compact representations of electromechanical interaction remain needed.
Answers are grounded in this paper and cite their sources.
A mass-spring model effectively represents the electromechanical interaction of ventricular repolarization and calcium transients under oscillatory pacing, suggesting calcium cycling drives EC coupling dynamics.
Cardiac EC coupling is triggered by rhythmic depolarizing current fronts originating from the sino-atrial node, and the way variability in rhythm is associated with variability in action potential duration (APD) and, in turn, in the variability of calcium transient amplitude (CTA) and contraction is a key determinant of beating stability. Sinusoidal-varying pacing rate is adopted here in order to establish whether APD and CTA oscillations, elicited in a human ventricular AP model (OR) under oscillatory pacing, are consistent with the dynamics of two coupled harmonic oscillators, e.g., a two-degree-of-freedom system of mass and springs (MS model). I show evidence that this is the case, and that the MS model, preliminarily fitted to OR behavior, retains key features of the physiological system, such as the dependence of APD and CTA oscillation amplitudes from average value and from beat-to-beat changes in pacing rate, and the phase relationship between them. The bi-directionality of coupling between APD and CTA makes it difficult to discriminate which one leads EC coupling dynamics under variable pacing. The MS model suggests that the calcium cycling, with its greater inertia chiefly determined by the SR calcium release, is the leading mechanism. I propose the present approach to also be relevant at the whole organ level, where the need of compact representations of electromechanical interaction, particularly in clinical practice, remains urgent.
No takes yet. Share an insight, caveat, or question.
Massimiliano Zaniboni (2022) studied Ventricular repolarization and calcium transient dynamics. Sinusoidal-varying pacing rate (oscillatory pacing) was evaluated on Action potential duration (APD) and calcium transient amplitude (CTA) oscillations. Oscillatory pacing in a human ventricular action potential model demonstrated that action potential duration and calcium transient amplitude oscillations behave as two coupled harmonic oscillators.
Synapse has enriched 10 related papers. Consider them for comparative context: