Key result
Sedation for electrical storm suppression lacks evidence as a review finds zero eligible studies.
Why the study?
Sedation is conventionally used for repeated electrical shocks, but evidence for its effectiveness in suppressing electrical storm remains limited.
Does sedative administration suppress ventricular fibrillation and ventricular tachycardia in patients with electrical storm?
Systematic Review
Does sedative administration suppress ventricular fibrillation and ventricular tachycardia in patients with electrical storm?
There is currently a lack of high-quality evidence from randomized or observational analytical studies to support the routine use of sedative drugs for arrhythmia suppression in patients with electrical storm.
Answers are grounded in this paper and cite their sources.
No evidence supports routine sedative use in electrical storm; leaves open efficacy and requires prospective trials.
Background: Electrical storm (ES) is defined as a condition in which ventricular tachycardia (VT) or ventricular fibrillation (VF) episodes requiring electrical shock or implantable cardioverter-defibrillator (ICD) shocks occur ≥3 times within 24 h. It is a life-threatening condition, and treatment options include antiarrhythmic drugs, sedation, circulatory support, and catheter ablation. Sedation is conventionally performed for repeated electrical shocks; however, evidence for its effectiveness in ES suppression remains limited. This scoping review aimed to assess whether the use of sedatives is beneficial for ES suppression. Methods and Results: This scoping review followed the PRISMA extension for scoping reviews (PRISMA-ScR) guidelines. Three online databases were searched to identify studies published from the inception of each database until September 18, 2024. To date, no randomized or quasi-randomized controlled trials or observational analytical studies have met the inclusion criteria for the use of sedation in patients with ES. Conclusions: This scoping review underscores the need for high-quality studies to enhance the level of evidence and bridge knowledge gaps, ultimately aiming to shift the care paradigm for patients with ES.
No takes yet. Share an insight, caveat, or question.
Kitai et al. (2025) conducted a systematic review in Electrical storm. Sedative administration (deep sedation) was evaluated on All-cause mortality, cardiac death, recurrence of VT or VF, and number of defibrillation shocks. Sedative administration for electrical storm suppression lacks evidence from randomized or observational analytical studies, as a scoping review identified zero eligible studies.