Why the study?
Does aortic clamping during valve replacement cause acute aortic dissection in patients with 'floppy' mitral valves?
Does aortic clamping during valve replacement cause acute aortic dissection in patients with 'floppy' mitral valves?
Answers are grounded in this paper and cite their sources.
Aortic clamping during valve replacement in patients with 'floppy' mitral valves can cause intimal tears and acute dissection, suggesting careful control of perfusion pressure and infrequent clamping.
Mitral regurgitation due to 'floppy' valves is frequently associated with areas of medical necrosis in the ascending aorta. Application of the aortic clamp to such an area during valve replacement may produce an intimal tear followed by acute dissection. This complication occurred in three patients and was treated successfully by repair of the tear in the two cases where the dissection was observed at the time of operation. Is is suggested that infrequent clamping of the aorta and careful control of the pefusion pressure may decrease the risk of intimal trauma and acute dissection.
No takes yet. Share an insight, caveat, or question.
McKay et al. (1976) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: