Why the study?
Two-dimensional selective excitation shortens 4D flow scan times by reducing the FOV, but its longer pulse duration decreases temporal resolution and underestimates peak flow values.
This is the authors' abstract. We don't add key points for this paper.
Purpose Two‐dimensional selective excitation (2DRF) allows shortening 4D flow scan times by reducing the FOV, but the longer 2DRF pulse duration decreases the temporal resolution, yielding underestimated peak flow values. Multiple k‐space lines per cardiac phase, n l ≥ 2, are commonly applied in 4D flow MRI to shorten the inherent long scan times. We demonstrate that 2DRF 4D flow with n l ≥ 2 can be easily combined with UNFOLD (UNaliasing by Fourier‐encoding the Overlaps using the temporaL Dimension), a technique that allows regaining nominally the temporal resolution of the respective acquisition with n l = 1, to assure peak flow quantification. Methods Two different 2DRF pulses with spiral k‐space trajectories were designed and integrated into a 4D flow sequence. Flow phantom experiments and 7 healthy control 4D flow in vivo measurements, with and without UNFOLD reconstructions, were compared with conventional reconstruction and 1D slab‐selective excitation (1DRF) by evaluating time‐resolved flow curves, peak flow, peak velocity, blood flow volume per cardiac cycle, and spatial aliasing. Results Applying UNFOLD to 4D flow imaging with 2DRF and reduced FOV increased the quantified in vivo peak flow values significantly by 3.7% ± 2.3% to 5.2% ± 2.4% ( P < .05). Accordingly, the peak flow underestimation of 2DRF scans compared with conventional 1DRF scans decreased with UNFOLD. Finally, 2DRF combined with UNFOLD accelerated the 4D flow acquisition 3.5 ± 1.4 fold by reducing the FOV and increasing the effective temporal resolution by 6.7% compared with conventional 1D selective excitation, with 2 k‐space lines per cardiac phase. Conclusion Two‐dimensional selective excitation combined with UNFOLD allows limiting the FOV to shorten 4D flow scan times and compensates for the loss in temporal resolution with 2DRF (Δ t = 64.8 ms) compared with 1DRF (Δ t = 43.2 ms), yielding an effective resolution of Δ t eff = 40.5 ms to enhance peak flow quantification.
Answers are grounded in this paper and cite their sources.
Combining 2D selective excitation with UNFOLD reconstruction in 4D flow MRI allows for reduced field of view and shorter scan times while compensating for loss in temporal resolution to enhance peak flow quantification.
No takes yet. Share an insight, caveat, or question.
Wink et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: