Key result
A systematic approach of repeat procedures with a second-generation cryoballoon using a different balloon size than the index procedure resulted in 70% of patients being free of recurrent AF at 1 year.
Why the study?
Does a staged variable balloon size strategy with a second-generation cryoballoon prevent atrial fibrillation recurrence in patients with recurrent paroxysmal atrial fibrillation after an index cryoballoon procedure?
Cohort (n=40)
No
Does a staged variable balloon size strategy with a second-generation cryoballoon prevent atrial fibrillation recurrence in patients with recurrent paroxysmal atrial fibrillation after an index cryoballoon procedure?
A staged variable balloon size strategy using a second-generation cryoballoon for redo ablation in recurrent paroxysmal atrial fibrillation is safe and achieves a 70% freedom from recurrence at 1 year.
Answers are grounded in this paper and cite their sources.
May support variable balloon sizing for redo cryoballoon ablation in recurrent paroxysmal AF; hypothesis-generating and requires randomized confirmation before practice change.
PURPOSE: Currently, information on the optimal approach of redo procedures for paroxysmal atrial fibrillation (PAF) is limited. Radiofrequency ablation is the preferred technique, with reported success rates of 50-70% at 1-2 years, whereas only few reports exist on redo cryoballoon (CB) ablations. We describe outcomes on a systematic approach of repeat procedures with a second-generation cryoballoon (CB-2) after a successful index CB ablation. Per protocol, a staged variable balloon size strategy was followed with a different balloon size during the redo as compared to the index procedure. Minimal follow-up was 12 months (median 17 months [IQR 14-39]). RESULTS: Overall, 120 pulmonary veins (PVs) (75%) showed chronic isolation: 64% (41/64) for first-generation cryoballoon (CB-1) and 82% (79/96) for CB-2 index procedures, respectively (p = 0.01). The overall mean number of reconnected PVs per patient was 1.0 (40/40): 1.4 for CB-1 and 0.7 for CB-2 index procedures (p = 0.008). Phrenic nerve palsies (n = 7) resolved before the end of the procedure. At 1 year, 70% of patients were free of recurrent AF. In multivariate analysis, the only independent predictor of recurrence was the number of prior cardioversions. CONCLUSIONS: A systematic approach of repeat procedures with a CB-2 using a different balloon size than during the index CB ablation is safe, with acceptable 1-year outcomes. Future comparative studies on the optimal redo technique and approach are warranted to further improve rhythm control in AF.
No takes yet. Share an insight, caveat, or question.
Westra et al. (2018) conducted a cohort in Recurrent paroxysmal atrial fibrillation (n=40). Second-generation cryoballoon (CB-2) ablation with variable balloon size was evaluated on Freedom from atrial fibrillation recurrence at 12 months. A systematic approach of repeat procedures with a second-generation cryoballoon using a different balloon size than the index procedure resulted in 70% of patients being free of recurrent AF at 1 year.