Key result
TAVR using the SAPIEN 3 in nonagenarians resulted in a similar 30-day composite early safety endpoint compared to younger patients, despite higher operative risk.
Why the study?
Does TAVR using the SAPIEN 3 prosthesis have similar early safety and mortality in nonagenarians compared to younger patients with severe aortic stenosis?
Cohort (n=85)
No
Does TAVR using the SAPIEN 3 prosthesis have similar early safety and mortality in nonagenarians compared to younger patients with severe aortic stenosis?
TAVR using the SAPIEN 3 prosthesis in nonagenarians yields acceptable 30-day mortality and early safety comparable to younger patients, though with higher rates of bleeding and vascular complications.
Answers are grounded in this paper and cite their sources.
Supports TAVR consideration in selected nonagenarians; leaves open need for randomized confirmation of safety.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study aimed to investigate the early clinical outcomes after TAVR using the SAPIEN 3 in nonagenarians. METHODS: A total of 97 consecutive patients underwent TAVR for severe AS between December 2015 and December 2016. Of these, 85 consecutive patients who underwent TAVR using the SAPIEN 3 were included. According to the age, patients were classified into age ≥ 90 years group (17 patients) or age < 90 years group (68 patients). The clinical outcomes including all-cause mortality and composite endpoint of early safety at 30 days were evaluated. CONCLUSIONS: The early mortality and safety after TAVR using the SAPIEN 3 in nonagenarians were similar and acceptable despite of higher operative risk.
No takes yet. Share an insight, caveat, or question.
Ichimoto et al. (2018) conducted a cohort in Severe aortic stenosis (n=85). Transcatheter aortic valve replacement (TAVR) using SAPIEN 3 in nonagenarians (≥90 years) vs. TAVR using SAPIEN 3 in patients <90 years was evaluated on Composite endpoint of early safety at 30 days (p=0.40). TAVR using the SAPIEN 3 in nonagenarians resulted in a similar 30-day composite early safety endpoint compared to younger patients, despite higher operative risk.
Synapse has enriched 10 related papers. Consider them for comparative context: