Key result
QRS dispersion after CRT-D implantation significantly increased compared to intrinsic mode (P<0.001) but did not correlate with arrhythmic events, whereas decreased QRS duration improved arrhythmias.
Why the study?
Does QRS dispersion after CRT-D implantation predict the incidence of arrhythmias in patients with heart failure?
Observational (n=45)
Does QRS dispersion after CRT-D implantation predict the incidence of arrhythmias in patients with heart failure?
Answers are grounded in this paper and cite their sources.
QRS dispersion after CRT-D implantation does not predict arrhythmia risk, whereas a decrease in QRS duration is associated with a lower incidence of arrhythmias.
Introduction: Heart failure (HF) is one of the major problems of health system in the countries. In a subgroup of these patients, cardiac resynchronization therapy defibrillator (CRT-D) improves the quality of life by enhancing the function of the left ventricle (LV) and preventing of arrhythmias. The present study intends to discuss the effect of CRT-D on the QRS dispersion, as a predisposing factor to arrhythmias. Methods: 45 patients treated with CRT-D during 2012-2015 were enrolled in this study. QRS dispersion in various V-V delays was measured and its association with the incidence of arrhythmias, at least six months after insertion, was assessed. Results: The results showed that QRS dispersion in the intrinsic mode was significantly lower than the other modes of the CRT-D device (P < 0.001). Besides, it was revealed that mean QRS duration in the intrinsic mode had a higher association with arrhythmic events than max QRS duration. QRS dispersion after CRT-D implantation had a significant increase compared to the intrinsic mode. However, it did not correlate with the arithmetic events. Further decrease in the duration of QRS after CRT-D implantation improved arrhythmias. Conclusion: QRS dispersion after CRT-D implantation is not an indicative of arrhythmia risk, and a decrease in the duration of QRS had a more significant effect on the incidence of arrhythmias.
No takes yet. Share an insight, caveat, or question.
Akbarzadeh et al. (2018) conducted an observational in Heart failure (n=45). Cardiac resynchronization therapy defibrillator (CRT-D) vs. Intrinsic mode was evaluated on QRS dispersion and incidence of arrhythmias (p=<0.001). QRS dispersion after CRT-D implantation significantly increased compared to intrinsic mode (P<0.001) but did not correlate with arrhythmic events, whereas decreased QRS duration improved arrhythmias.
Synapse has enriched 10 related papers. Consider them for comparative context: