Key result
Patient-specific simulation using CARDIOSIM software demonstrated a 5% rise in total cardiac output and a leftward shift of pressure-volume loops during simulated LVAD support.
Why the study?
Can preoperative simulation using CARDIOSIM software guide intervention and predict outcome in advanced heart failure patients requiring LVAD insertion?
Case Report (n=1)
No
Can preoperative simulation using CARDIOSIM software guide intervention and predict outcome in advanced heart failure patients requiring LVAD insertion?
Preoperative patient-specific simulation using CARDIOSIM software may assist multidisciplinary teams in planning LVAD insertion for advanced heart failure patients.
May aid LVAD planning in advanced HF; hypothesis-generating and requires prospective validation before practice change.
Clinical practice heavily relies on results from randomized controlled trials, which may not reflect completely individual patients. Patient-specific modelling has received increasing attention in recent years. Although still far from clinical application on a daily basis, the potential of this approach is significant. The treatment of advanced heart failure may benefit from a modelling framework to guide device treatment and predict outcome. The role of mechanical circulatory support as a long-term solution is increasing in view of the evolving technology and worsening heart failure patient population. Therefore, a preoperative strategy with the ability to predict the course of events in a simulation setting may be justified. Here we present a heart failure patient discussed at a multidisciplinary team meeting whose outcome was compared with simulations carried out with CARDIOSIM© software to investigate the role of this approach as a planning strategy to guide intervention and predict outcome. The clinical decision process is complex and many factors are involved. Patient-specific modelling may have a role to play as part of a preoperative planning strategy with more quantitative evaluation to smooth decision-making.
No takes yet. Share an insight, caveat, or question.
Capoccia et al. (2018) conducted a case report in Advanced heart failure (n=1). CARDIOSIM software simulation of LVAD support vs. Baseline diseased status was evaluated on Hemodynamic parameters (cardiac output, pressure-volume loops). Patient-specific simulation using CARDIOSIM software demonstrated a 5% rise in total cardiac output and a leftward shift of pressure-volume loops during simulated LVAD support.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: