Key result
Patient-specific modelling using CARDIOSIM© successfully simulated the haemodynamic effects of LVAD support, demonstrating its potential value as a quantitative tool for preoperative planning in advanced heart failure.
Why the study?
Does patient-specific computational simulation accurately model hemodynamic responses to LVAD support in advanced heart failure patients?
Case Report (n=3)
Does patient-specific computational simulation accurately model hemodynamic responses to LVAD support in advanced heart failure patients?
Patient-specific computational modeling can simulate hemodynamic responses to LVAD support, potentially aiding in preoperative planning and clinical decision-making for advanced heart failure patients.
Hypothesis-generating for simulation-guided LVAD planning; requires prospective validation before clinical adoption.
BACKGROUND: Modelling and simulation may become clinically applicable tools for detailed evaluation of the cardiovascular system and clinical decision-making to guide therapeutic intervention. Models based on pressure-volume relationship and zero-dimensional representation of the cardiovascular system may be a suitable choice given their simplicity and versatility. This approach has great potential for application in heart failure where the impact of left ventricular assist devices has played a significant role as a bridge to transplant and more recently as a long-term solution for non eligible candidates. RESULTS: was the software used for this purpose. The study was based on retrospective analysis of haemodynamic data previously discussed at a multidisciplinary meeting. The outcome of the simulations addressed the value of a more quantitative approach in the clinical decision process. CONCLUSIONS: Although previous experience, co-morbidities and the risk of potentially fatal complications play a role in clinical decision-making, patient-specific modelling may become a daily approach for selection and optimisation of device-based treatment for heart failure patients. Willingness to adopt this integrated approach may be the key to further progress.
No takes yet. Share an insight, caveat, or question.
Capoccia et al. (2018) conducted a case report in Advanced heart failure (n=3). Simulation using CARDIOSIM© vs. Standard clinical decision-making was evaluated on Haemodynamic parameters (EDV, ESV, Ea/Ees ratio) during simulated LVAD support. Patient-specific modelling using CARDIOSIM© successfully simulated the haemodynamic effects of LVAD support, demonstrating its potential value as a quantitative tool for preoperative planning in advanced heart failure.