Why the study?
While large studies had documented outcomes of transvenous lead extraction focusing on laser and mechanical methods, no large series had addressed results obtained with rotational lead extraction tools.
What are the efficacy and safety outcomes of mechanical and rotational transvenous lead extraction techniques in patients requiring lead extraction?
What are the efficacy and safety outcomes of mechanical and rotational transvenous lead extraction techniques in patients requiring lead extraction?
Mechanical and rotational transvenous lead extraction techniques demonstrate high clinical success (97.0%) and low major complication rates (1%), suggesting they are highly effective and safe.
Supports expanded use of mechanical and rotational extraction; extends observational data but leaves randomized comparisons open.
AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.
No takes yet. Share an insight, caveat, or question.
Starck et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: