Key result
E-wave-derived energy for suction-initiated early rapid filling via kinematic modeling was equivalent to invasive P-V-defined filling energy.
Why the study?
Is filling energy computed from non-invasive Doppler E-waves equivalent to that derived from invasive P-V loops in assessing diastolic function?
Observational (n=12)
Is filling energy computed from non-invasive Doppler E-waves equivalent to that derived from invasive P-V loops in assessing diastolic function?
Non-invasive Doppler E-wave-derived energy for early rapid filling is equivalent to invasive P-V-defined filling energy, providing a novel mechanism-based index of diastolic function.
Answers are grounded in this paper and cite their sources.
May enable non-invasive diastolic filling assessment; leaves open prospective validation before clinical adoption.
Pressure-volume (P-V) loop-based analysis facilitates thermodynamic assessment of left ventricular function in terms of work and energy. Typically these quantities are calculated for a cardiac cycle using the entire P-V loop, although thermodynamic analysis may be applied to a selected phase of the cardiac cycle, specifically, diastole. Diastolic function is routinely quantified by analysis of transmitral Doppler E-wave contours. The first law of thermodynamics requires that energy (ε) computed from the Doppler E-wave (εE-wave) and the same portion of the P-V loop (εP-V E-wave) be equivalent. These energies have not been previously derived nor have their predicted equivalence been experimentally validated. To test the hypothesis that εP-V E-wave and εE-wave are equivalent, we used a validated kinematic model of filling to derive εE-wave in terms of chamber stiffness, relaxation/viscoelasticity, and load. For validation, simultaneous (conductance catheter) P-V and echocadiographic data from 12 subjects (205 total cardiac cycles) having a range of diastolic function were analyzed. For each E-wave, εE-wave was compared with εP-V E-wave calculated from simultaneous P-V data. Linear regression yielded the following: εP-V E-wave=αεE-wave+b (R2=0.67), where α=0.95 and b=6e(-5). We conclude that E-wave-derived energy for suction-initiated early rapid filling εE-wave, quantitated via kinematic modeling, is equivalent to invasive P-V-defined filling energy. Hence, the thermodynamics of diastole via εE-wave generate a novel mechanism-based index of diastolic function suitable for in vivo phenotypic characterization.
No takes yet. Share an insight, caveat, or question.
Mossahebi et al. (2010) conducted an observational in Diastolic function (n=12). E-wave-derived energy (εE-wave) via kinematic modeling vs. Invasive P-V-defined filling energy (εP-V E-wave) was evaluated on Equivalence of εP-V E-wave and εE-wave (R2=0.67). E-wave-derived energy for suction-initiated early rapid filling via kinematic modeling was equivalent to invasive P-V-defined filling energy.