Key result
Regadenoson significantly increased coronary blood flow (P < 0.05) and allowed visual and quantitative detection of perfusion defects for up to 10 minutes in dogs with non-flow limiting stenosis.
Why the study?
Does regadenoson allow detection of coronary artery stenosis during myocardial contrast echocardiography in an open-chest dog model?
Does regadenoson allow detection of coronary artery stenosis during myocardial contrast echocardiography in an open-chest dog model?
p-value: p=< 0.05
Regadenoson can be effectively used as a vasodilator stress agent during myocardial contrast echocardiography to detect physiologically significant coronary stenosis in a preclinical model.
Hypothesis-generating for regadenoson in myocardial contrast echocardiography; human trials needed before clinical adoption.
AIMS: Regadenoson is comparable to adenosine in pharmacologic radionuclide stress tests but has not been studied with stress myocardial contrast echocardiography. This study assessed the haemodynamic profile and ability of regadenoson, a novel selective A(2A) receptor agonist, to detect coronary artery stenosis during myocardial contrast echocardiography. METHODS AND RESULTS: Myocardial contrast echocardiography was performed to measure myocardial blood volume, myocardial blood flow velocity, and total regional myocardial blood flow before and after administration of regadenoson (5 µg kg(-1), 10 s bolus) in 10 open-chest dogs with mild-to-moderate coronary stenosis that was not flow limiting at rest. Regadenoson decreased blood pressure but did not change heart rate. It increased coronary blood flow significantly (P < 0.05) for 30 min, which was attenuated in proportion to coronary stenosis severity. Whereas myocardial blood volume maximally increased by 0.5-0.75-fold in the control region, it did not change in the region supplied by the non-flow limiting stenosis. Perfusion defects were visually and quantitatively detectable for as long as 10 min after administration of regadenoson. No arrhythmias were noted with regadenoson either prior to or during myocardial contrast echocardiography. CONCLUSION: Regadenoson can be used as a vasodilator stress agent with myocardial contrast echocardiography to detect the presence of physiologically significant coronary stenosis. The optimum time for image acquisition was 3-10 min after drug administration.
No takes yet. Share an insight, caveat, or question.
Le et al. (2011) studied Mild-to-moderate coronary stenosis (n=10). Regadenoson vs. Baseline / control region was evaluated on Haemodynamic profile and ability to detect coronary artery stenosis (myocardial blood volume, flow velocity, and total regional flow) (p=< 0.05). Regadenoson significantly increased coronary blood flow (P < 0.05) and allowed visual and quantitative detection of perfusion defects for up to 10 minutes in dogs with non-flow limiting stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: