Why the study?
Does microvolt T-wave alternans better predict 2-year mortality compared to QRS duration in heart failure patients meeting MADIT II criteria?
Population
177 heart failure patients with MADIT II characteristics and sinus rhythm
Comparison
Microvolt T-wave alternans exercise test vs 12-lead ECG QRS duration (>120 ms vs <=120 ms)
Design
Cohort
Follow-up
average 20+/-6 months
Authors
Loading...
TWA may aid mortality risk stratification in MADIT II-like HF; leaves open whether it refines ICD selection.
Does microvolt T-wave alternans better predict 2-year mortality compared to QRS duration in heart failure patients meeting MADIT II criteria?
Microvolt T-wave alternans is superior to QRS duration for risk-stratifying MADIT II-like heart failure patients to identify those most and least likely to benefit from ICD therapy.
Bloomfield et al. (2004) studied this question.