Home blood pressure readings are generally lower than clinic readings with pronounced and unpredictable inter-individual variation, supporting the broader use of home monitoring in hypertension evaluation.
Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter-individual scatter was pronounced and unpredictable from the hypertensive organ damages. It is argued, that home readings should be used to greater extent in the evaluation of patients with hypertension.