Key result
Blood collection through a peripheral venous catheter significantly increased coagulation activation markers (TAT and F1+2) compared to repeated venepunctures (p<0.01 at 10:00 and 14:00).
Why the study?
PV catheters are frequently used for serial blood sampling but may increase markers of coagulation activation and inflammation; whether this increase stems from vessel wall irritation or diurnal variation is unknown.
Does blood sampling from a peripheral venous catheter compared to repeated venepunctures affect markers of coagulation, inflammation, and endothelial function in healthy subjects?
Does blood sampling from a peripheral venous catheter compared to repeated venepunctures affect markers of coagulation, inflammation, and endothelial function in healthy subjects?
Blood collection through a peripheral venous catheter induces coagulation activation compared to repeated venepunctures, which may confound biomarker studies.
Peripheral venous catheter sampling risks confounding coagulation biomarker results; leaves open optimal venepuncture protocols for future studies.
Peripheral venous (PV) catheters are often used for serial blood sampling, but studies suggest that PV catheters increase markers of coagulation activation and inflammation. Whether the increase is caused by irritation of the vessel wall or diurnal variation is unknown. We therefore compared the effects of a PV catheter and repeated venepunctures on markers of coagulation, inflammation, and endothelial function.A PV catheter was inserted at 07:45 in a hand vein in 10 healthy subjects, and blood samples were collected at 8:00, 10:00, 12:00, and 14:00. In the contralateral arm, blood was simultaneously obtained by venepunctures. Measures of coagulation, i.e., activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen, prothrombin fragment 1 + 2 (F1 + 2) and thrombin-antithrombin (TAT), inflammation, i.e., interleukin 6 (IL-6) and C-reactive protein (CRP), and endothelial function, i.e., plasminogen activator inhibitor 1 (PAI-1), tissue plasminogen activator (tPA), von Willebrand factor (vWF), and tissue factor (TF) were measured in plasma.The concentrations of TAT and F1 + 2 were significantly increased (10:00; p < .01, 12:00; p < .05, and 14:00; p < .01) in PV catheter samples compared with venepuncture samples. There was a minor increase in PT and INR and no increase in APTT, fibrinogen, CRP, PAI-1, tPA, vWF, and TF, with no differences between sampling methods. IL-6 concentrations increased in many PV catheter samples and venepuncture samples, but the response varied between the subjects.Blood collection through a PV catheter induces coagulation activation, whereas endothelial function is not affected. More studies are needed to disclose the effect of blood sampling on IL-6.
No takes yet. Share an insight, caveat, or question.
Landgrebe et al. (2019) studied Healthy subjects (n=10). Peripheral venous catheter vs. Repeated venepunctures was evaluated on Markers of coagulation, inflammation, and endothelial function (p=<0.01). Blood collection through a peripheral venous catheter significantly increased coagulation activation markers (TAT and F1+2) compared to repeated venepunctures (p<0.01 at 10:00 and 14:00).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: