Why the study?
Does a catheter-infusion system provide equivalent accuracy to individual venipunctures for serial determinations of PF4 and beta TG?
Does a catheter-infusion system provide equivalent accuracy to individual venipunctures for serial determinations of PF4 and beta TG?
A simple catheter-infusion system is equivalent to multiple venipunctures for serial measurement of platelet-specific proteins, avoiding patient discomfort.
Answers are grounded in this paper and cite their sources.
Supports catheter-based serial sampling to minimize discomfort; leaves open need for validation before routine adoption.
Platelet factor 4 (PF4) and beta thromboglobulin (beta TG) are platelet-specific proteins which are released upon platelet aggregation and which can be accurately measured by radioimmunoassay. We devised a catheter-infusion system that enables serial determinations of these proteins. In 20 subjects (10 healthy volunteers and 10 patients with stable coronary artery disease), we compared samples collected by individual venipunctures with those simultaneously obtained by means of a simple catheter-infusion system. At least 5 samples were obtained over a period of time which was as long as 60 min, and at least 30 min. Subjects with stable coronary artery disease were selected so that they would be expected to have stable and normal PF4 and beta TG levels. Thus, elevations of either PF4 or beta TG would represent artifacts secondary to sampling technique. Analysis of the results demonstrated that the catheter-infusion system was equivalent to individual venipunctures for determination of PF4 and beta TG. 16.8% of samples obtained via the catheter and 17.2% of those obtained by individual venipunctures were spuriously elevated. A second series of studies were performed to refine the technique further by examining the impact of infusion rate and the addition of citrate phosphate dextrose (CPD) to the infusate. Ten additional subjects had catheter systems utilized in both arms simultaneously. The addition of CPD resulted in significantly less abnormal values at slower infusion rates (1 and 2.5 cc/min). At 5 cc/min D5/w or saline alone are suitable. These investigations confirm that this simple catheter system is equivalent to individual venipunctures for determination of PF4 and beta TG while avoiding patient discomfort.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Strauss et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: