Key result
Primary prevention ICDs show diminished benefit under contemporary medical therapy in LVEF 30-35%.
Why the study?
Primary prevention ICD trials were conducted over 20 years ago, and modern therapies have lowered mortality and sudden cardiac death rates, questioning whether current inclusive criteria remain appropriate.
Does primary prevention ICD therapy provide significant mortality benefit in contemporary heart failure patients with ejection fraction 30-35% on optimal medical therapy?
Does primary prevention ICD therapy provide significant mortality benefit in contemporary heart failure patients with ejection fraction 30-35% on optimal medical therapy?
This review challenges current guidelines by proposing that primary prevention ICD implantation should be restricted to highest-risk patients within the EF 30-35% subgroup.
Answers are grounded in this paper and cite their sources.
May support restricting primary prevention ICDs to highest-risk EF 30-35% patients; leaves open confirmation by contemporary RCTs.
While the efficacy of the intracardiac defibrillators (ICDs) for primary prevention is not disputed, the relevant studies were carried out a long time ago. Most pertinent trials, including MADIT-II, SCD-Heft, and DEFINITE, recruited patients more than 20 years ago. Since then, improved therapeutic modalities including, in addition to cardiac resynchronization therapy, mineralocorticoid receptor antagonists, angiotensin receptor-neprilysin inhibitors, and, most recently, inhibitors of sodium-glucose cotransporter 2, have lowered present-day rates of mortality and of sudden cardiac death. Thus, nowadays, ICD therapy may be less effective than previously reported, and not as beneficial as many people currently believe. However, criteria for ICD implantation remain very inclusive. The patient must (only) be symptomatic and have ejection fraction (EF) ≤ 35%. The choice of EF 35% is notable because the average EF in all large trials was much lower, and clinical benefit was mainly limited to EF ≤ 30%. This EF cut-off value defines a substantial portion of potential ICD recipients. It seems therefore reasonable to limit ICD eligibility criteria in the EF range 30-35% to patients at highest risk only. We discuss and present some rational criteria to assist the clinician in improving risk stratification for preventive ICD implantation.
No takes yet. Share an insight, caveat, or question.
Deckers et al. (2021) conducted a review in Heart failure with reduced ejection fraction. Implantable Cardioverter Defibrillator (ICD) vs. Contemporary medical therapy was evaluated. Primary prevention ICDs may be less beneficial than previously reported due to contemporary medical therapies, warranting more stringent selection criteria for patients with ejection fraction 30-35%.
Synapse has enriched 10 related papers. Consider them for comparative context: