Why the study?
Does the single-beat method accurately detect pharmacologically induced changes in right ventricular contractility compared to the multiple-beat method in anesthetized pigs?
Does the single-beat method accurately detect pharmacologically induced changes in right ventricular contractility compared to the multiple-beat method in anesthetized pigs?
The single-beat method failed to accurately detect pharmacologically induced changes in right ventricular contractility compared to the reference multiple-beat method in a porcine model.
Answers are grounded in this paper and cite their sources.
Single-beat RV contractility assessment warrants caution during pharmacologic modulation; leaves open validation against multiple-beat methods in humans.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Lambermont et al. (2004) studied this question. Single-beat method (Eessb) vs. Multiple-beat method (Eesmb) was evaluated on End-systolic elastance (Ees) changes induced by dobutamine and esmolol.