Key result
In excised canine hearts, the oxygen cost of mechanical energy was time-invariant, but myocardial oxygen consumption decreased with increasing quick-release speed despite the same partial pressure-volume area.
The study demonstrates that while the oxygen cost of mechanical energy is time-invariant, consistent with the time-varying elastance model, the decrease in VO2 with increasing quick-release speed reveals an inconsistency in the model.
Reveals inconsistency in time-varying elastance model; leaves open relevance to intact hearts.
We studied whether the oxygen cost of mechanical energy is time-invariant in the excised, cross-circulated canine heart. The total mechanical energy generated by ventricular contraction can be quantified by the total pressure-volume area (PVA) according to the time-varying elastance model. In this model, mechanical energy generated until a specified time (t) during systole can be quantified by the partial pressure-volume area, PVA(t). PVA(t) was obtained by quickly releasing ventricular volume at a varied time during isovolumic contraction. The quick release aborted further development of mechanical energy. We found that PVA(t) at a constant end-diastolic volume linearly correlated with myocardial oxygen consumption (VO2). This indicates that the oxygen cost of mechanical energy is time-invariant. However, we also found that the slope of the VO2-PVA(t) relation decreased with increasing quick-release speed. This indicates a decrease in VO2 by the quick release despite the same PVA(t). The time-invariant oxygen cost of mechanical energy is consistent with the time-varying elastance model of the ventricle, but the decreased VO2 with increasing quick-release speed despite the same PVA(t) is not.
No takes yet. Share an insight, caveat, or question.
Yasumura et al. (1989) studied Excised, cross-circulated canine heart. Quick release of ventricular volume at varied times during isovolumic contraction vs. Different quick-release speeds was evaluated on Myocardial oxygen consumption (VO2) relation to partial pressure-volume area (PVA(t)). In excised canine hearts, the oxygen cost of mechanical energy was time-invariant, but myocardial oxygen consumption decreased with increasing quick-release speed despite the same partial pressure-volume area.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: