Key result
An anterior ablation line successfully eliminated perimitral flutter and produced bidirectional block in two cardiac allograft recipients.
Why the study?
Does an anterior ablation line eliminate perimitral flutter and produce bidirectional block in cardiac allograft recipients?
Case Report (n=2)
Does an anterior ablation line eliminate perimitral flutter and produce bidirectional block in cardiac allograft recipients?
An anterior ablation line may be an effective and feasible approach for treating perimitral flutter in cardiac allograft recipients.
Answers are grounded in this paper and cite their sources.
May support anterior ablation for perimitral flutter in cardiac allografts; leaves open need for prospective validation.
Perimitral atrial flutter in cardiac allograft recipients is uncommon. In general, mitral isthmus ablation can be quite challenging in all patients with perimitral flutter, including the subset of patients who present following left atrial ablation for atrial fibrillation. We report 2 cases where an anterior ablation line was easily performed to eliminate perimitral flutter and produce bidirectional block.
No takes yet. Share an insight, caveat, or question.
Makanjee et al. (2009) conducted a case report in Perimitral atrial flutter after heart transplant (n=2). Anterior ablation line was evaluated on Elimination of perimitral flutter and production of bidirectional block. An anterior ablation line successfully eliminated perimitral flutter and produced bidirectional block in two cardiac allograft recipients.
Synapse has enriched 10 related papers. Consider them for comparative context: