Answers are grounded in this paper and cite their sources.
Systematic design procedure optimizes harmonic compensators in grid-connected photovoltaic inverters, suggesting standards compliance.
<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> The injection of low-harmonic current to the electrical grid is nowadays regulated by international standards. In order to accomplish these standards, selective harmonic compensation is carried out in grid-connected photovoltaic inverters by means of resonant harmonic compensators. This paper gives a systematic design procedure for selecting the gains and parameters of these harmonic compensators. Other factors considered in the design process include frequency deviation, grid synchronization, and transient response. Both a design example meeting the requirements of grid interconnection and selected experimental results from a digital-signal-processor-based laboratory prototype are also reported. </para>
No takes yet. Share an insight, caveat, or question.
Castilla et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: