Key result
The ratio of early diastolic mitral flow to early diastolic lateral mitral annulus velocity (E/Ea) demonstrated the strongest correlation with maximum left atrial pressure and mean left atrial pressure among all evaluated echocardiographic variables.
Why the study?
Does the echocardiographic E/Ea ratio accurately estimate left atrial pressure in dogs with mitral regurgitation?
Does the echocardiographic E/Ea ratio accurately estimate left atrial pressure in dogs with mitral regurgitation?
The echocardiographic E/Ea ratio provides a precise and instant non-invasive estimation of maximum and mean left atrial pressure in dogs with mitral regurgitation.
Answers are grounded in this paper and cite their sources.
Supports non-invasive LAP estimation in canine MR; hypothesis-generating and requires prospective validation before clinical adoption.
Non-invasive and immediate estimation of left atrial pressure (LAP) is very useful for the management of mitral regurgitation (MR), and many reports have assessed echocardiographic estimations of LAP to date. However, it has been unclear of which examination and evaluate article possess the best accuracy for the MR severity. The present research aims to establish the echocardiographic estimation equation of LAP that is well applicable for clinical MR dogs. After the chordae tendineae rupture was experimentally induced via left atriotomy in six healthy beagle dogs (three males and three females, two years old, weighing between 9.8 to 12.8 kg), a radio telemetry transmitter catheter was inserted, which allows the continuous recordings of LAP without the use of sedation. Approximately 5 weeks after the surgery, echocardiographic examination, indirect blood pressure measurement, measurement of plasma atrial natriuretic peptide (ANP) and LAP measurement by way of the radio telemetry system was performed simultaneously. Subsequently, simple linear regression equations between LAP and each variable were obtained, and the equations were evaluated whether to be applicable for clinical MR dogs. As a result, the ratio of early diastolic mitral flow to early diastolic lateral mitral annulus velocity (E/Ea) had the strongest correlation as maximum LAP=7.03*(E/Ea)-54.86 (r=0.74), and as mean LAP=4.94*(E/Ea)-40.37 (r=0.70) among the all variables. Therefore, these two equations associated with E/Ea should bring more precise and instant estimations of maximum and mean LAP in clinical MR dogs.
No takes yet. Share an insight, caveat, or question.
Ishikawa et al. (2011) studied Mitral Valve Regurgitation (n=263). Echocardiographic estimation of left atrial pressure (E/Ea ratio) vs. Direct left atrial pressure measurement via radio telemetry was evaluated on Correlation between the ratio of early diastolic mitral flow to early diastolic lateral mitral annulus velocity (E/Ea) and maximum left atrial pressure (r=0.74, p=<0.05). The ratio of early diastolic mitral flow to early diastolic lateral mitral annulus velocity (E/Ea) demonstrated the strongest correlation with maximum left atrial pressure and mean left atrial pressure among all evaluated echocardiographic variables.
Synapse has enriched 10 related papers. Consider them for comparative context: