Key result
Paced complex biventricular children show similar adverse event rates to univentricular circulation.
Why the study?
Pacing in a univentricular circulation has been associated with worsened outcomes, prompting investigation into long-term outcomes compared with a complex biventricular circulation.
Does pacing in children with a complex biventricular circulation result in different outcomes compared to pacing in a univentricular circulation?
Cohort (n=89)
No
Does pacing in children with a complex biventricular circulation result in different outcomes compared to pacing in a univentricular circulation?
Children with a univentricular or complex biventricular circulation who require pacemakers have a similar risk of long-term adverse events, with nonapical lead position predicting worse outcomes in the biventricular group.
Answers are grounded in this paper and cite their sources.
Similar adverse outcomes support comparable monitoring across circulations; leaves open optimal lead positioning in biventricular patients.
Objective: Pacing in a univentricular circulation has been associated with worsened outcomes. We investigated the long-term outcomes of pacing in children with a univentricular circulation compared to a complex biventricular circulation. We also identified predictors of adverse outcomes. Methods: A retrospective study of all children with major congenital heart disease who underwent pacemaker implantation under the age of 18 years between November 1994 and October 2017. Results: Eighty-nine patients were included; 19 with a univentricular and 70 with a complex biventricular circulation. A total of 96% of pacemaker systems were epicardial. Median follow up was 8.3 years. The incidence of adverse outcome was similar between the two groups. Five (5.6%) patients died and two (2.2%) underwent heart transplantation. Most adverse events occurred within the first 8 years after pacemaker implantation. Univariate analysis identified five predictors of adverse outcomes in the patients in the biventricular but none in the univentricular group. The predictors of adverse outcome in the biventricular circulation were a right morphologic ventricle as the systemic ventricle, age at first congenital heart disease (CHD) operation, number of CHD operations, and female gender. The nonapical lead position was associated with a much higher risk of an adverse outcome. Conclusions: Children with a pacemaker and a complex biventricular circulation have similar survival to the ones with a pacemaker and a univentricular circulation. The only modifiable predictor was the epicardial lead position on the paced ventricle, emphasizing the importance of apical placement of the ventricular lead.
No takes yet. Share an insight, caveat, or question.
Spentzou et al. (2023) conducted a cohort in Major congenital heart disease requiring pacemaker implantation (n=89). Pacemaker implantation in complex biventricular circulation vs. Pacemaker implantation in univentricular circulation was evaluated on Incidence of adverse events (composite of death, transplantation, ventricular assist device implantation, ventricular dysfunction, upgrade to multisite pacing, or deterioration of NYHA class) (HR 0.72, 95% CI 0.28-1.83, p=0.484). Children with a pacemaker and a complex biventricular circulation had a similar incidence of adverse outcomes compared to those with a univentricular circulation.