Key result
A prolonged PR interval (>200 ms) was independently associated with an increased risk of atrial fibrillation recurrence after catheter ablation compared to a normal PR interval (HR 1.81).
Why the study?
Does a prolonged PR interval predict recurrence of atrial fibrillation in patients undergoing catheter ablation?
Cohort (n=224)
No
Does a prolonged PR interval predict recurrence of atrial fibrillation in patients undergoing catheter ablation?
Hazard Ratio: 1.81 (95% CI 1.07–3.05)
Absolute Event Rate: 33.9% vs 20.5%
p-value: p=0.027
A prolonged PR interval (>200 ms) is an independent predictor of atrial fibrillation recurrence following first-time catheter ablation.
It has been demonstrated that a prolonged PR interval is associated with an increased risk of AF. However, the impact of a prolonged PR interval on recurrence of paroxysmal atrial fibrillation (AF) after catheter ablation is not clear. A total of 112 patients with a prolonged PR interval (PR > 200 ms) (PPR group) and 112 age- and gender-matched control patients (on a 1:1 basis) with a normal PR interval (NPR group) were included in this study. AF recurrence was defined as the occurrence of confirmed atrial tachyarrhythmia lasting more than 30 seconds beyond 3 months after catheter ablation in the absence of any antiarrhythmic treatment. During a mean follow-up period of 10.9 ± 5.5 months (range, 3-18 months), 61 patients (27.2%) developed recurrence of AF. The recurrence rate was higher in the PPR group than in the NPR group (33.9% versus 20.5%, respectively; P = 0.018). Cox regression analysis with adjustment for age, body mass index, valvular heart disease, left atrial diameter, and pulmonary vein isolation identified only a prolonged PR interval as an independent predictor of recurrence of AF (hazard ratio, 1.81; 95% confidence interval, 1.07-3.05; P = 0.027). Patients with a prolonged PR interval were at an increased risk of AF recurrence after catheter ablation.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2014) conducted a cohort in Paroxysmal atrial fibrillation (n=224). Prolonged PR interval (> 200 ms) vs. Normal PR interval (≤ 200 ms) was evaluated on Recurrence of atrial fibrillation (confirmed atrial tachyarrhythmia lasting >30 seconds beyond 3 months after ablation) (HR 1.81, 95% CI 1.07-3.05, p=0.027). A prolonged PR interval (>200 ms) was independently associated with an increased risk of atrial fibrillation recurrence after catheter ablation compared to a normal PR interval (HR 1.81).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: