Key result
SAECG parameters show no difference between German Shepherds and Boxers, establishing breed reference values.
Why the study?
What are the normal reference values for SAECG parameters in healthy German Shepherd and Boxer dogs?
Cross-Sectional (n=47)
No
What are the normal reference values for SAECG parameters in healthy German Shepherd and Boxer dogs?
Absolute Event Rate: 76.11% vs 76.21%
p-value: p=>0.05
This study establishes normal reference values for SAECG in German Shepherd and Boxer dogs, finding no significant differences between the breeds, which will aid in future research on hereditary ventricular arrhythmias.
Signal-averaged electrocardiogram (SAECG) identifies ventricular late potentials (LP), low-amplitude electrical signals that are markers of slow cardiac conduction in fibrous myocardium, consisting in a predictive factor for sudden death in dogs at risk of sustained ventricular tachycardia. The aim of this study was to establish reference values of SAECG for German Shepherd and Boxer dogs. SAECG was performed in 19 German Shepherd and 28 Boxer client-owned dogs, and parameters analyzed were QRSd (duration of filtered QRS), LAS<40μV (duration of low-amplitude signals in terminal portion of filtered QRS) and RMS40 (root square of mean voltage over the last 40 milliseconds of filtered QRS), with two different filters (25-250 Hz and 40-250 Hz). Statistical analyses was achieved by T Student test (p<0.05) to identify differences between the two groups and between the values obtained with the two filters. No statistical difference was found in SAECG variables between the two breeds with the two different filters (p>0.05). Achieving normal values of SAECG in German Shepherd and Boxer dogs is important to further research late potentials in animals of these breeds with hereditary ventricular tachycardia or arrhythmogenic cardiomyopathy and identification of individuals at high risk of cardiac-related sudden death.
No takes yet. Share an insight, caveat, or question.
Chamas et al. (2014) conducted a cross-sectional in Healthy (establishing reference values for late potentials / slow cardiac conduction screening) (n=47). German Shepherd breed vs. Boxer breed was evaluated on QRSd (duration of filtered QRS) with 40-250 Hz filter (p=>0.05). German Shepherd and Boxer dogs showed no statistically significant differences in signal-averaged electrocardiogram parameters, including QRS duration (76.11 ms vs 76.21 ms, p>0.05), establishing normal reference values for these breeds.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: