Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
March 13, 2006Blood Pressure Monitoring

Automated blood pressure measurement in routine clinical practice

View Full Paper
Ask AI
Bookmark
Share

Key result

Automated blood pressure measurements taken while the patient rested alone (142/80 mmHg) were significantly lower than manual mercury sphygmomanometer readings (163/86 mmHg, P<0.001).

Why the study?

Does automated blood pressure measurement reduce the white-coat effect compared to a conventional mercury sphygmomanometer in patients with hypertension?

Population

50 consecutive patients referred to a specialist for management of hypertension.

Comparison

Automated blood pressure measurement using the… vs Conventional mercury sphygmomanometer.

Design

Cross-sectional, random order

Authors

MMMartin G. MyersGeneral Cardiology

Discussion

Loading...

Member takes

Overview

Automated BP may reduce white-coat effect; leaves open need for outcome trials before practice change.

Study Design

Type

RCT (n=50)

Randomization

Random order

Structured PICO

Does automated blood pressure measurement reduce the white-coat effect compared to a conventional mercury sphygmomanometer in patients with hypertension?

P
Population
50 patients (56% women, mean age 62) referred to a specialist for hypertension management, evaluated during their first visit.
I
Intervention
Automated blood pressure measurement using the BpTRU recorder (initial reading with observer present, followed by five readings resting quietly alone).
C
Comparator
Conventional mercury sphygmomanometer (manual blood pressure taken in duplicate).
O
Outcome
Blood pressure measurement values (mmHg).surrogate

Main Result

Absolute Event Rate: 142% vs 163%

p-value: p=<0.001

Automated blood pressure measurement taken while the patient rests alone significantly reduces the white-coat effect compared to manual mercury sphygmomanometer readings.

Cite This Study

Martin G. Myers (2006) conducted an RCT in Hypertension (n=50). Automated blood pressure recorder (BpTRU) vs. Conventional mercury sphygmomanometer was evaluated on Mean systolic blood pressure (mmHg) (p=<0.001). Automated blood pressure measurements taken while the patient rested alone (142/80 mmHg) were significantly lower than manual mercury sphygmomanometer readings (163/86 mmHg, P<0.001).

synapsesocial.com/papers/6a209e20e307124fcfcd2f3ehttps://doi.org/10.1097/01.mbp.0000200481.64787.c0
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparison of the oscillometric blood pressure monitor (BPM-100 Beta ) with the auscultatory mercury sphygmomanometer2001 · 83 citations
  2. 2Recommendations for Blood Pressure Measurement in Humans and Experimental Animals2005 · 4,003 citations
  3. 3Ambulatory Blood Pressure1999 · 351 citations
  4. 4Has conventional sphygmomanometry ended with the banning of mercury?2002 · 43 citations