Key result
A method combining 1MDS filtration, PEG precipitation, and RT-PCR successfully concentrated and detected caliciviruses in water samples, with a detection limit of 0.75 to 1.5 PFU in 40 liters.
A new method using filtration, PEG precipitation, and RT-PCR can effectively concentrate and detect caliciviruses in various water types, with a limit of detection of 0.75-1.5 PFU in 40L of finished water.
Answers are grounded in this paper and cite their sources.
May aid waterborne virus surveillance research; leaves open performance in naturally contaminated field samples.
Human caliciviruses (HuCVs) cause waterborne outbreaks of gastroenteritis. Standard indicators of a safe water supply do not adequately predict contamination of water by viruses, including HuCVs. We developed a method to concentrate and detect HuCVs in water samples by using a cultivable primate calicivirus (Pan-1) as a model. Viable Pan-1 was seeded in different types of water and then filtered with a 1MDS filter, eluted with beef extract (BE), and reconcentrated by polyethylene glycol (PEG) precipitation. The viruses in the final samples were tested by plaque assay or by reverse transcription (RT)-PCR following extraction of the RNA with Trizol. Pan-1 was more sensitive to high-pH treatment than poliovirus was; a pH 9.0 BE solution was found to recover 35% more viable Pan-1 than a pH 9.5 BE solution recovered. Pan-1 was recovered from small volumes of deionized, finished, ground, and surface waters at efficiencies of 94, 73, 67, and 64%, respectively, when samples were assayed after elution without further concentration. When larger volumes of water (up to 40 liters) were tested after elution and concentration with PEG, 38, 19, and 14% of the seeded Pan-1 were recovered from finished, ground, and surface waters, respectively. The limit of detection of Pan-1 by RT-PCR was estimated to be 0.75 to 1.5 PFU in 40 liters of finished water. This method may be adapted for monitoring HuCVs in drinking water and other types of water for public health safety.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2000) studied Water contamination by caliciviruses. 1MDS filtration, beef extract elution, PEG precipitation, and RT-PCR was evaluated on Limit of detection of Pan-1 by RT-PCR in 40 liters of finished water. A method combining 1MDS filtration, PEG precipitation, and RT-PCR successfully concentrated and detected caliciviruses in water samples, with a detection limit of 0.75 to 1.5 PFU in 40 liters.
Synapse has enriched 10 related papers. Consider them for comparative context: