Key result
Chronic kidney disease with dialysis significantly increased the risk of cardiac implantable electronic device infection during index hospitalization (aOR 3.78) compared to patients with normal renal function.
Why the study?
Does chronic kidney disease increase the risk of CIED infection in patients receiving new CIED implantation?
Cohort (n=38,354)
Yes
Does chronic kidney disease increase the risk of CIED infection in patients receiving new CIED implantation?
Odds Ratio: 3.78 (95% CI 2.37–6.02)
Absolute Event Rate: 1.83% vs 0.37%
p-value: p=<0.001
Chronic kidney disease, particularly when requiring dialysis, is a significant independent risk factor for CIED infection during the index hospitalization.
CKD with dialysis was associated with higher CIED infection risk; leaves open whether targeted prevention improves outcomes.
Chronic kidney disease (CKD) increased the incident cardiac implantable electronic device (CIED) infection, but risk factors of CIED infection in CKD patients remain unclear.Patients who received new CIED implantation between January 1, 1997 and December 31, 2011 were selected from the Taiwan National Health Insurance Database and were divided into 3 groups: patients with normal renal function, CKD patients without dialysis, and CKD patient with dialysis. Two outcomes, CIED infection during index hospitalization and within 1 year after discharge, were evaluated.This study included 38,354 patients, 35,060 patients in normal renal function group, 1927 patients in CKD without dialysis group, and 1367 patients in CKD with dialysis group. CKD patients without dialysis (adjusted odds ratio [aOR], 2.14, 95% confidence interval [CI], 1.32-3.46) and CKD patients with dialysis (aOR, 3.78, 95% CI, 2.37-6.02) increased incident CIED infection during index hospitalization compared to patients with normal renal function. Use of steroid (aOR: 2.74, 95% CI, 1.08-6.98) increased the risk of CIED infection in CKD patients without dialysis while chronic obstructive pulmonary disease (COPD) (aOR: 2.76, 95% CI, 1.06-7.16) increased the risk of CIED infection in CKD patient with dialysis during index hospitalization.CKD is a risk of CIED infection during index hospitalization. Use of steroid and COPD are important risks factors for CIED infection in CKD patients.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2016) conducted a cohort in Cardiac implantable electronic device (CIED) infection (n=38,354). Chronic kidney disease with dialysis vs. Normal renal function was evaluated on CIED infection during index hospitalization (aOR 3.78, 95% CI 2.37-6.02, p=<0.001). Chronic kidney disease with dialysis significantly increased the risk of cardiac implantable electronic device infection during index hospitalization (aOR 3.78) compared to patients with normal renal function.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: